Elevação dos níveis séricos de endotelina-1 após implante de stend coronariano em humanos : um marcador de disfunção endotelial não associado à reestenose
dc.contributor.advisor | Wainstein, Marco Vugman | pt_BR |
dc.contributor.author | Gonçalves, Sandro Cadaval | pt_BR |
dc.date.accessioned | 2007-06-06T19:14:20Z | pt_BR |
dc.date.issued | 2003 | pt_BR |
dc.identifier.uri | http://hdl.handle.net/10183/8252 | pt_BR |
dc.description.abstract | Introdução: A reestenose intra-stent ocorre basicamente por uma resposta proliferativa da parede vascular à lesão. Além de ser um marcador de disfunção endotelial, a endotelina-1 (ET-1) exerce atividade proliferativa sobre as células musculares lisas. Evidências experimentais sugerem que a ET-1 possa contribuir para fisiopatogenia da reestenose. Porém, a relação entre os níveis de ET-1 com o implante de stent coronariano e a reestenose intrastent em humanos não está definida. Objetivo: Avaliar o comportamento dos níveis plasmáticos da ET-1 em pacientes submetidos a implante de stent coronariano e determinar se há associação desses com a ocorrência de reestenose. Métodos: Foram incluídos 41 pacientes (44 stents), encaminhados para revascularização coronariana eletiva com implante de stent, por indicação da equipe assistente. Os níveis séricos de ET-1 foram dosados pelo método de ELISA antes do procedimento, logo após e seis meses após o procedimento, quando se realizou nova angiografia quantitativa para avaliar a presença de reestenose. Os níveis de ET-1 foram comparados nos grupos com e sem reestenose e correlacionados com a perda luminal tardia. Resultados: A incidência de reestenose angiográfica foi de 41%. Ocorreu um aumento significativo da ET-1 logo após o procedimento em ambos os grupos (P<0,001), retornando a valores semelhantes aos basais no sexto mês. Não houve diferença significativa entre os grupos com e sem reestenose quanto aos valores de ET-1 em nenhum dos momentos analisados. Não houve correlação entre os níveis de ET-1 e a perda luminal tardia. Conclusões: Ocorre um aumento significativo dos níveis de ET-1 após o implante de stent, possivelmente por ser a ET-1 um marcador da disfunção endotelial provocada pela lesão. Entretanto, não houve uma associação entre os níveis de ET-1 e a ocorrência de reestenose pós-stent em humanos. | pt_BR |
dc.description.abstract | Background: Experimental evidence suggests that endothelin-1 (ET-1) levels may play a role in the occurrence of restenosis following percutaneous revascularization procedures. However, the relationship between serum ET-1 with coronary stent implantation and restenosis in humans is not well defined yet. The objective of this study was to evaluate the serum levels of ET-1 in patients submitted to coronary stenting and to determine if there is an association between ET-1 levels and the occurrence of in-stent restenosis. Methods: 41 patients (44 stents) submitted to elective coronary stent implantation were included in the study. Serum ET-1 levels were measured right before and after the procedure and after 6 months. ET-1 levels were compared in patients with and without restenosis and correlated with late luminal loss. Results: The incidence of restenosis was 41%. A significant increase in ET-1 levels right after the procedure was observed in both groups (P < 0.001), with return to basal values after 6 months. No difference was observed between the groups, with and without restenosis, in ET-1 levels pre-procedure, post-procedure or at 6-months. No correlation was observed between late luminal loss and ET-1 levels. Conclusions: There is a significant increase in ET-1 levels right after coronary stenting, probably as a marker of endothelial dysfunction associated arterial lesion. However, there was no association between ET-1 levels and in-stent restenosis in humans. | en |
dc.format.mimetype | application/pdf | |
dc.language.iso | por | pt_BR |
dc.rights | Open Access | en |
dc.subject | Endotélio vascular | pt_BR |
dc.subject | Endotelina-1 | pt_BR |
dc.subject | Reestenose coronária | pt_BR |
dc.subject | Stents | pt_BR |
dc.title | Elevação dos níveis séricos de endotelina-1 após implante de stend coronariano em humanos : um marcador de disfunção endotelial não associado à reestenose | pt_BR |
dc.type | Dissertação | pt_BR |
dc.contributor.advisor-co | Pinto Ribeiro, Jorge | pt_BR |
dc.identifier.nrb | 000572210 | pt_BR |
dc.degree.grantor | Universidade Federal do Rio Grande do Sul | pt_BR |
dc.degree.department | Faculdade de Medicina | pt_BR |
dc.degree.program | Programa de Pós-Graduação em Ciências da Saúde: Cardiologia e Ciências Cardiovasculares | pt_BR |
dc.degree.local | Porto Alegre, BR-RS | pt_BR |
dc.degree.date | 2003 | pt_BR |
dc.degree.level | mestrado | pt_BR |