Simultaneous quantification of lycopene, B-carotene, retinol and alfa-tocopherol in plasma after a simple extraction procedure : stability study and application to human volunteers
dc.contributor.author | Charão, Mariele Feiffer | pt_BR |
dc.contributor.author | Moro, Angela Maria | pt_BR |
dc.contributor.author | Brucker, Natália | pt_BR |
dc.contributor.author | Bulcão, Rachel Picada | pt_BR |
dc.contributor.author | Baierle, Marília | pt_BR |
dc.contributor.author | Freitas, Fernando | pt_BR |
dc.contributor.author | Durgante, Juliano | pt_BR |
dc.contributor.author | Nascimento, Sabrina Nunes do | pt_BR |
dc.contributor.author | Bubols, Guilherme Borges | pt_BR |
dc.contributor.author | Saldiva, Paulo Hilario Nascimento | pt_BR |
dc.contributor.author | Bohrer, Denise | pt_BR |
dc.contributor.author | Garcia, Solange Cristina | pt_BR |
dc.date.accessioned | 2013-06-15T01:49:21Z | pt_BR |
dc.date.issued | 2012 | pt_BR |
dc.identifier.issn | 0103-5053 | pt_BR |
dc.identifier.uri | http://hdl.handle.net/10183/72503 | pt_BR |
dc.description.abstract | Um método para quantificação simultânea de licopeno, β-caroteno, retinol e α-tocoferol por cromatografia líquida de alta eficiência (HPLC) com detecção no visível/fluorescente e eluição isocrática foi otimizado e validado. O método consiste de extração líquido-líquido rápida e simples e posterior quantificação do sobrenadante extraído por HPLC. Alíquotas de plasma foram estocadas a –20°C por três meses para estudo da estabilidade. Aplicação metodológica foi realizada em amostras fornecidas por pintores e indivíduos não expostos a tintas (n = 75). O ensaio foi linear para todas as vitaminas analisadas (r > 0,99). Precisões intradia e interdia apresentaram coeficiente de variação (CV) menor que 5%. Exatidões variaram de 0,29 a –5,80% e recuperações entre 92,73 e 101,97%. Amostras de plasma e sobrenadante extraído foram estáveis por até 60 dias a –20°C. Foi demonstrada uma diminuição significativa nas concentrações de licopeno, β-caroteno e retinol em indivíduos expostos quando comparados com os não-expostos (p < 0,05). O método é simples, reprodutível, preciso, exato e sensível, e pode ser utilizado na rotina de laboratórios clínicos. | pt_BR |
dc.description.abstract | A method for the simultaneous quantification of lycopene, β-carotene, retinol and α-tocopherol by high-performance liquid chromatography (HPLC) with Vis/fluorescence detection with isocratic elution was optimized and validated. The method consists of a rapid and simple liquid-liquid extraction procedure and a posterior quantification of extracted supernatants by HPLC. Aliquots of plasma were stored at –20°C for three months for stability study. The methodology was applied to samples from painters and individuals not exposed to paints (n = 75). The assay was linear for all vitamins (r > 0.99). Intra- and inter-run precisions were obtained with coefficient of variation smaller than 5%. The accuracies ranged from 0.29 to –5.80% and recoveries between 92.73 and 101.97%. Plasma samples and extracted supernatants were stable for 60 days at –20°C. A significant decrease of lycopene, β-carotene and retinol concentrations in plasma from exposed individuals compared to non-exposed individuals (p < 0.05) was observed. The method is simple, reproducible, precise, accurate and sensitive, and can be routinely utilized in clinical laboratories. | en |
dc.format.mimetype | application/pdf | |
dc.language.iso | eng | pt_BR |
dc.relation.ispartof | Journal of the Brazilian Chemical Society. São Paulo. Vol. 23, n. 8 (2012), p. 1441-1449 | pt_BR |
dc.rights | Open Access | en |
dc.subject | Retinol | en |
dc.subject | Retinol | pt_BR |
dc.subject | α-tocopherol | en |
dc.subject | Licopeno | pt_BR |
dc.subject | Carotenóides | pt_BR |
dc.subject | Lycopene | en |
dc.subject | Métodos analíticos | pt_BR |
dc.subject | β-carotene | en |
dc.subject | HPLC | en |
dc.subject | Liquid-liquid extraction | en |
dc.title | Simultaneous quantification of lycopene, B-carotene, retinol and alfa-tocopherol in plasma after a simple extraction procedure : stability study and application to human volunteers | pt_BR |
dc.type | Artigo de periódico | pt_BR |
dc.identifier.nrb | 000873512 | pt_BR |
dc.type.origin | Nacional | pt_BR |
Files in this item
This item is licensed under a Creative Commons License
-
Journal Articles (40361)Health Sciences (10795)