Mostrar el registro sencillo del ítem

dc.contributor.authorPiva, Jefferson Pedropt_BR
dc.contributor.authorMenna Barreto, Sérgio Saldanhapt_BR
dc.contributor.authorAmantea, Sergio Luispt_BR
dc.contributor.authorZelmanovitz, Flaviopt_BR
dc.date.accessioned2012-08-24T01:38:13Zpt_BR
dc.date.issued2000pt_BR
dc.identifier.issn0021-7557pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/54371pt_BR
dc.description.abstractObjetivo: Estudar a distribuição do radioaerossol 99mTc-DTPA utilizando heliox ou oxigênio como veículos de nebulização na cintilografia pulmonar ventilatória de crianças e adolescentes com doença pulmonar obstrutiva crônica (DPOC). Material e métodos: Ensaio clínico randomizado e controlado. Incluídos pacientes (5 a 18 anos) com DPOC que, entre março de 1996 e setembro de 1998, necessitaram realizar cintilografia pulmonar ventilatória. A obstrução ao fluxo aéreo foi quantificada pela espirometria. Aleatoriamente foram distribuídos em dois grupos, conforme o gás utilizado na nebulização durante a cintilografia: heliox (hélio 80% e oxigênio 20%), ou oxigênio. Os resultados foram expressos através do slope (inclinação da curva de aquisição cumulativa de radioatividade pulmonar) e pela concentração cumulativa máxima de radioatividade obtida nos campos pulmonares. Determinou-se, ainda, o tamanho médio das partículas de 99mTc-DTPA geradas pelos dois gases. Resultados: Foram alocados dez pacientes em cada grupo, sem diferenças (p>0,05) quanto ao gênero, diagnóstico etiológico, presença de desnutrição, médias de peso, estatura, superfície corpórea, ou nos resultados da espirometria. A média dos slopes do grupo heliox (5.039 +1.652) foi maior (p=0,018) que no grupo oxigênio (3.410 +1.100). Pacientes do grupo heliox com acentuada redução do fluxo aéreo apresentaram um slope médio maior (p=0,017) do que o dos pacientes do grupo oxigênio com diminuição do fluxo aéreo. Os pacientes dos grupos do heliox e do oxigênio, sem evidências de obstrução ao fluxo aéreo na espirometria, não apresentaram diferenças nas médias dos slopes (p= 0,507). O diâmetro médio das partículas do 99mTc-DTPA geradas pelo heliox foi de 2,13 (+0,62mm), que é maior (p=0,004) que o daquelas geradas pelo oxigênio (0,88 +0,99 mm). Conclusões: O heliox como veículo de nebulização na cintilografia pulmonar de crianças e adolescentes com DPOC promove uma melhor dispersão e distribuição do radioaerossol, do que a obtida pelo oxigênio. Esses benefícios do heliox, em relação aos do oxigênio, tornam-se mais evidentes em presença de obstrução das vias aéreas inferiores, enquanto que na sua ausência, não se observa diferença na dispersão e na distribuição de radioaerossol. As partículas geradas pelo heliox e pelo oxigênio, apesar de apresentarem diferenças significativas em seus diâmetros médios, encontram-se dentro da amplitude recomendada (1 a 5mm). Portanto, essa possível diferença não justifica os efeitos demonstrados pelo heliox neste estudo.pt_BR
dc.description.abstractObjective: To study the distribution of the radioaerosol of 99mTc- DTPA when the heliox gas is used as an inhalation vehicle during the pulmonary ventilatory scintigraphy in children and adolescents with chronic obstructive lung disease (COPD). Material and methods: Clinical randomized and controlled trial. Patients (from 5 to 18 years old) with COPD needing pulmonary scintigraphic study, between March 1996 and September 1998, were included. The obstruction of the lower airway was measured by pulmonary function study. The patients were randomized in two groups: heliox (helium 80% and oxygen 20%) or oxygen, according to the gas used as a vehicle to nebulize the particles during the scintigraphic study. The results of the scintigraphic study were expressed by the slope of the curve (the inclination of the curve of cumulative pulmonary radioactivity) and by the maximal cumulative radioactivity achieved in the lungs areas. The mean diameter of the 99mTc-DTPA particles generated by heliox and oxygen were measured by laser diffraction. Results: Ten patients were allocated in each group, without any statistical difference (p>0.05) in respect to gender, main diagnosis, signs of undernutrition, the mean values of weight, height, body area and the results of the pulmonary function study. The mean slope in the heliox group (5.039 +1.652) showed a significant difference (p=0.018) when compared to the mean slope of the oxygen group (3,410 +1,100). The patients with reduction of the airway flow in the heliox group obtained a mean slope with significant difference (p=0.017) when compared to the mean slope of the patients in the oxygen group with the same reduction in airway flow. The patients of the heliox group and oxygen group without airway obstruction flow did not show any statistical difference when they were compared on the basis of either the means of the slopes (p= 0.507) or the means of the cumulative radiation in the lung fields (p=0.795). The mean diameter of the particles of 99mTc- DTPA generated by heliox was 2.13 (+0.62mm), with a statistical difference (p=0.004) when compared with the mean diameter of the particles generated when oxygen was used as a vehicle (0,88 +0,99 mm). Conclusions: When heliox was used as a vehicle in the scintigraphic study of children and adolescents with DPOC, it showed a better distribution and dispersion of the 99mTc-DTPA into the lungs than that obtained when oxygen was used. The benefits of heliox over oxygen are more evident in the presence of lower airway obstruction flow. Without airway obstruction flow we could not demonstrate any difference in the distribution and in the radiation activity into the lungs. The mean diameters of the particles of 99mTc-DTPA generated by heliox and oxygen showed a significant difference. In spite of this, the mean diameters observed in both groups were included in the recommended range (between 1 and 5 mm). Therefore, the observed differences between the particles generated by both gases could not justify the effects of heliox demonstrated in this study.en
dc.format.mimetypeapplication/pdf
dc.language.isoporpt_BR
dc.relation.ispartofJornal de pediatria. Vol. 76, n. 1 (2000), p. 17-26pt_BR
dc.rightsOpen Accessen
dc.subjectPneumopatias obstrutivaspt_BR
dc.subjectHeliumen
dc.subjectAsmapt_BR
dc.subjectOxygen inhalation therapyen
dc.subjectRespiratory therapyen
dc.subjectOxigenoterapiapt_BR
dc.subjectObstructive lung diseasesen
dc.subjectHelioterapiapt_BR
dc.subjectCintilografiapt_BR
dc.subjectAsthmaen
dc.subjectAdministration by inhalationen
dc.subjectCriançapt_BR
dc.titleUso da mistura de hélio e oxigênio no estudo da ventilação de crianças com doença pulmonar obstrutiva crônicapt_BR