Mostrar el registro sencillo del ítem

dc.contributor.advisorPigatto, João Antonio Tadeupt_BR
dc.contributor.authorAndrade, Maria Cristina Caldart dept_BR
dc.date.accessioned2012-06-15T01:36:17Zpt_BR
dc.date.issued2011pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/49695pt_BR
dc.description.abstractA aferição da pressão intraocular (PIO) é importante para o diagnóstico e acompanhamento de doenças oculares. Métodos fidedignos para quantificar a PIO de maneira acurada têm sido buscados. Com o aparecimento de tonômetros portáteis, a avaliação da pressão intraocular em equinos tem se intensificado e os diferentes princípios de aferição têm sido comparados. Este estudo objetivou a comparação entre a tonometria de aplanação, realizada com o Tono-Pen Avia®, e tonometria de rebote, realizada com o Tonovet®, em equinos da raça Crioula. Além disso, a utilização, ou não, do cachimbo como método de contenção também foi comparada e submetida à análise estatística. Foram avaliados 30 cavalos com idades entre dois e 20 anos, machos ou fêmeas. Exame oftálmico prévio foi realizado com teste da lágrima de Schirmer, prova da fluoresceína, biomicroscopia com lâmpada de fenda e oftalmoscopia direta. A tonometria de aplanação foi realizada, no mínimo, 30 minutos após a tonometria de rebote. A pressão intraocular média do Tonovet® foi maior, 36,82 ± 5,91mmHg com cachimbo e 30,04 ± 3,19mmHg sem. A do Tono-Pen Avia® foi de 26,43 ± 5,48 mmHg com cachimbo e 23,10 ±4,01mmHg sem. Todos os resultados diferiram estatisticamente entre si. Quando comparados os sexos, o Tono-Pen Avia® não mostrou diferenças, enquanto o Tonovet® mostrou pressões maiores para cavalos castrados e garanhões, e menores para éguas (p<0,001) com a utilização do cachimbo. Não há correlação entre a idade dos cavalos e os valores de PIO, independente do aparelho (p > 0,05). Os valores da PIO com o Tonovet® foram maiores do que os obtidos com o Tono-Pen Avia®. A contenção dos animais com cachimbo eleva a pressão intraocular em equinos.pt_BR
dc.description.abstractIntraocular pressure evaluation is important for diagnosis and control of ophthalmic diseases. Accurate methods to quantify intraocular pressure have been searched. With the development of handheld tonometers, equine intraocular pressure evaluation has been intensified and the different principles of measurement have been compared. The objective of this study was to compare the applanation tonometry, taken with the Tono- Pen Avia® and the rebound tonometry, taken with the Tonovet® in adult “crioulo” breed horses. The age, gender and the use of upper lip twitch as a restraint method was also surveyed and submitted to statistical analysis. Thirty horses, aged two to 20, male or female were evaluated. A previous ophthalmic examination was performed with Schirmer tear test, fluoresceine test, slit lamp biomicroscopy and direct ophthalmoscopy in all animals. Applanation tonometry was performed, at least, 30 minutes after rebound tonometry. Intraocular pressure mean values measured with the Tonovet® was higher, 36,82±5,91mmHg with the lip twitch and 30,04±3,19mmHg without. Tonopen Avia® mean values were 26,43±5,48mmHg with the lip twitch and 23,10±4,1mmHg without. All results was statistical different between themselves. When genders were compared the Tono-Pen Avia® revealed no difference, however the Tonovet® showed higher pressures for male horses (p‹0,001) with the use of lip twitch. There was no correlation between age and intraocular pressure in “crioulo” horses, regardless of the equipment tested (p›0,05). Intraocular pressure mean values measured with the Tonove®t were higher than those obtained with the Tono-Pen Avia®. The restraint of animals with upper lip twitch increases equine intraocular pressure.en
dc.format.mimetypeapplication/pdf
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectHorseen
dc.subjectOftalmologia Veterináriapt_BR
dc.subjectEqüinos : Raça crioulapt_BR
dc.subjectIntraocular pressureen
dc.subjectTonometria ocularpt_BR
dc.subjectTonometryen
dc.subjectPressão intraocularpt_BR
dc.subjectTonoveten
dc.subjectTono-pen aviaen
dc.titleEstudo comparativo entre a tonometria de rebote e a tonometria de aplanação em equinos da raça crioula (Equus cabbalus)pt_BR
dc.typeDissertaçãopt_BR
dc.identifier.nrb000851185pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentFaculdade de Veterináriapt_BR
dc.degree.programPrograma de Pós-Graduação em Ciências Veterináriaspt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2011pt_BR
dc.degree.levelmestradopt_BR