Show simple item record

dc.contributor.authorGhedini, Rodrigo Guellnerpt_BR
dc.contributor.authorMargarites, Ane Freitaspt_BR
dc.contributor.authorFelix, Elaine Aparecidapt_BR
dc.contributor.authorXavier, Rogerio Gastalpt_BR
dc.contributor.authorAndrade, Cristiano Feijópt_BR
dc.date.accessioned2012-03-27T01:20:30Zpt_BR
dc.date.issued2010pt_BR
dc.identifier.issn0102-8650pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/38000pt_BR
dc.description.abstractObjetivo: Desenvolver um modelo animal de estimulação elétrica diafragmática capaz de gerar um suporte ventilatório adequado através da implantação direta de eletrodos no diafragma (eletroventilação). Métodos: Seis coelhas da raça Nova Zelândia (2–3 kg) foram colocadas em ventilação mecânica. Através de uma laparotomia foram identificados os pontos motores em ambas as cúpulas diafragmáticas, seguido pela implantação dos eletrodos para estimulação diafragmática. Foram testados dois tipos de eletrodos de acordo com a condução do estímulo elétrico: unipolar e bipolar. Os eletrodos foram posicionados em diferentes ocasiões nos mesmos animais e testados com intensidades de corrente de 20, 26 e 32 mA, sendo cada uma delas repetidas três vezes durante 10 ciclos respiratórios com intervalo de 1 minuto entre cada ciclo e repouso de 5 minutos para nova intensidade de corrente. Foram registradas a relação entre a intensidade de corrente e o volume de ar inspirado. Resultados: Os eletrodos estimularam adequadamente o diafragma com um volume de ar inspirado até 4,5 vezes maior no modo bipolar e de 3,5 vezes no modo unipolar em relação à linha de base. Conclusão: Este modelo demonstrou ser efetivo para o estudo do desempenho do diafragma sob diferentes estimulações elétricas e diferentes tipos de eletrodos.pt_BR
dc.description.abstractPurpose: To develop an animal model of diaphragmatic electrical stimulation able to generate an appropriate ventilatory support through the direct implantation of electrodes in the diaphragm (electroventilation). Methods: Six New Zealand female rabbits (2-3 kg) were placed on mechanical ventilation. Then, a laparotomy was performed in order to identify the motor points in each hemidiaphragm, followed by the implantation of the electrodes for diaphragmatic stimulation. We tested two types of electrodes according to the conduction of electrical stimulation: unipolar and bipolar. The electrodes were placed on different occasions in the same animals and tested with current intensities of 20, 26 and 32 mA. Each current intensity was repeated three times for 10 respiratory cycles with 1 minute interval between each cycle, and 5 minutes for new current intensity. We recorded the relationship between current intensity and inspiratory volume. Results: The electrodes adequately stimulate the diaphragm and obtain inspired volumes using different intensity currents. The bipolar electrode generated inspiratory volumes as high as 4.5 times of baseline while the unipolar electrode reached up to 3.5 times of baseline. Conclusion: This model has proved to be effective for studying the performance of the diaphragm under different electrical stimulations using different set of electrodes.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoengpt_BR
dc.relation.ispartofActa cirúrgica brasileira. São Paulo. Vol. 25, n. 6 (nov./dez. 2010), p. 475-478pt_BR
dc.rightsOpen Accessen
dc.subjectEstimulação elétricapt_BR
dc.subjectElectric Stimulationen
dc.subjectDiaphragmen
dc.subjectDiafragmapt_BR
dc.subjectPulmonary Ventilationen
dc.subjectVentilação pulmonarpt_BR
dc.subjectCoelhospt_BR
dc.subjectRabbitsen
dc.subjectExperimentação animalpt_BR
dc.titleDevelopment of a new experimental model of intramuscular electrical stimulation of the diaphragm in rabbitspt_BR
dc.title.alternativeDesenvolvimento de um novo modelo experimental de estimulação elétrica intramuscular do diafragma em coelhos pt
dc.typeArtigo de periódicopt_BR