dc.description.abstractObjetivo: Avaliar as características microscópicas do efeito do laser diodo de Arsenieto de Gálio-Alumínio (AsGaAl - 830 ηm), aplicado no período de ativação e consolidação de mandíbulas de ovelhas submetidas a distração osteogênica. Métodos: Dezoito ovinos foram submetidos a procedimento cirúrgico para colocação de distrator ósseo em região de mandíbula do lado esquerdo, sendo divididos em três grupos: 1 – Controle; 2 – Irradiação de laser no período de ativação; 3 – Irradiação de laser no período de contenção. As irradiações foram feitas em cinco seções em dias alternados, com doses de 4,0J/cm2 em quatro pontos pré-determinados, somando 16J por seção. Após quatro dias de latência no pós-operatório, 10 dias de ativação do distrator (1 mm/dia) e 21 dias de contenção os animais foram mortos e as peças removidas para análise microscópica. Resultados: Os resultados foram que os grupos irradiados com laser (AsGaAl) apresentaram maior disposição de trabéculas ósseas mineralizadas em relação ao grupo controle, contudo, no Grupo 2 foi observada a presença de tecido cartilaginoso. Conclusão: O laser atuou de forma mais favorável quando utilizado no período de consolidação, após o alongamento ósseo.pt_BR
dc.description.abstractPurpose: To analyze the microscopic characteristics of the effect of Gallium-Aluminum Arsenid diode laser (GaAlAs - 830 ηm) applied during the activation and consolidation period to ovine mandibles submitted to distraction osteogenesis. Methods: Eighteen sheep underwent surgery in order to have bone distractors implanted in the left side of the jaw area. They were divided into three groups: 1 – Control; 2 – Laser irradiation during the activation period; 3 – Laser irradiation during the fixation period. The irradiation was carried out in five sessions, on every other day, with 4,0J/cm2 doses applied to four pre-established areas, totaling 16J per session. After four days of latency under post-operative care, ten days of distractor activation (at 1mm/day) and twenty-one days of fixation the animals were sacrificed and the devices removed for microscopic analysis. Results: The groups that received laser irradiation (GaAlAs) presented a greater amount of mineralized bone trabeculae when compared to the Control Group. Despite that, cartilaginous tissues were also found in Group 2. Conclusion: The laser has been more favorable when used in the consolidation period, after bone elongation.en
dc.format.mimetypeapplication/pdf
dc.language.isoengpt_BR
dc.relation.ispartofActa cirúrgica brasileira. São Paulo. Vol. 22, n. 2 (Mar./Apr. 2007), p. 92-97pt_BR
dc.rightsOpen Accessen
dc.subjectLaser na odontologiapt_BR
dc.subjectLasersen
dc.subjectBone lengtheningen
dc.subjectMandibula : Cirurgiapt_BR
dc.subjectWound healingen
dc.subjectSheepen
dc.titleBone tissue microscopic findings related to the use of diode laser (830ηm) in ovine mandible submitted to distraction osteogenesispt_BR