dc.description.abstractObjetivo: Avaliar as complicações pré e pós-vitrectomia, sua correlação com o tempo de permanência do núcleo no vítreo e a acuidade visual final, bem como as complicações a longo prazo. Métodos: Estudo retrospectivo de 12 pacientes que apresentavam fragmentos do cristalino no vítreo pósfacectomia, submetidos a vitrectomia no Serviço de Oftalmologia do Hospital de Clínicas de Porto Alegre (HCPA) entre novembro de 1994 e junho de 2000. Resultados: Após a queda do núcleo no vítreo, 5 pacientes apresentaram edema corneano, 3 uveíte, 8 glaucoma, 1 descolamento de retina e todos tiveram redução da acuidade visual. Submetidos à vitrectomia, no pós-operatório imediato 2 apresentavam hifema, 6 glaucoma, 2 descolamento de retina, 1 phthisis bulbi, 1 edema macular cistóide, 2 perfluorocarbono na câmara anterior e 7 edema corneano. No pós-operatório tardio, a maioria das complicações se resolveram (média de 6 meses). O tempo de permanência do núcleo luxado foi menor que 15 dias para 3 pacientes e maior que 15 dias para 9 pacientes. Conclusão: Os resultados sugerem que os fragmentos do cristalino retidos na cavidade vítrea devem ser removidos prontamente para impedir a resposta inflamatória, melhorando, assim, o prognóstico visual.pt_BR
dc.description.abstractPurpose: To evaluate the complications before and after vitrectomy, their correlation with the time the lens remained in the vitreous cavity, and final visual acuity. The long-term complications were also evaluated. Methods: Retrospective study of 12 patients who had lens material in the vitreous after cataract surgery. The patients underwent vitreous surgery from November 1994 to June 2000 at the Ophthalmology Service of the Hospital de Clínicas de Porto Alegre (HCPA). Results: After the displacement of the nucleus into the vitreous cavity, 5 patients had corneal edema, 3 had uveitis, 8 glaucoma, 1 retinal detachment, and all patients had reduced visual acuity. After vitrectomy, 2 patients had hyphema, 6 glaucoma, 2 retinal detachment, 1 phthisis bulbi, 1 cystoid macular edema, 2 perfluorcarbon in the anterior chamber, and 7 corneal edema. Almost all complications resolved on the longterm evaluation (mean 6 months). The length of time the nucleus remained in the vitreous cavity was less than 15 days in 3 patients and more than 15 days in 9 patients. Conclusion: The results suggest that the fragments retained in the vitreous cavity should be promptly removed to prevent the inflammatory response and to improve the visual prognosis.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.relation.ispartofArquivos brasileiros de oftalmologia. São Paulo. Vol. 65, n. 4 (jul./ago. 2002), p. 435-439pt_BR
dc.rightsOpen Accessen
dc.subjectCrystalline lens/pathologyen
dc.subjectCristalinopt_BR
dc.subjectLuxaçõespt_BR
dc.subjectLens subluxationen
dc.subjectVitrectomiapt_BR
dc.subjectVitrectomyen
dc.subjectPreoperative careen
dc.subjectCuidados pós-operatóriospt_BR
dc.subjectPostoperative complicationsen
dc.subjectComplicações pós-operatóriaspt_BR
dc.subjectRefracao ocularpt_BR
dc.subjectVisual acuityen
dc.subjectVitreous bodyen
dc.subjectCorpo vítreopt_BR
dc.subjectRetrospective studiesen
dc.titleComplicações da luxação do cristalino para a cavidade vítreapt_BR