dc.description.abstractO presente trabalho avaliou o pH de géis clareadores de consultório em diferentes tempos após a ativação. Neste estudo, foram analisados cinco agentes clareadores : HP Blue 20% - FGM (HPB20%); HP Blue 35% - FGM (HPB35%); Whitegold Office 35 %- Dentsply (WGO35%); MixOne Supreme – Villevie (MOS35%); Pola Office + 37,5% -- SDI (PO37,5%). Para a mensuração do pH, os géis clareadores foram ativados e realizou-se as medições do pH nos seguintes tempos: tempo 0 - logo após a manipulação; 30 minutos; 45 minutos e 7 dias após a ativação do gel clareador. Para análise do pH foi utilizado um pHmetro (DM23 Digimed) calibrado em solução tampão pH 4,00 e pH 6,86. Essa calibração foi realizada a cada medida em cada um dos géis clareadores, no qual três gramas do gel manipulado foram depositados em um tubo de ensaio cada. Esse processo foi repetido cinco vezes para cada agente clareador (n=5). Logo após a manipulação, a média das medições de pH foi de: HPB20% -9,3048; HPB35% - 8,4936; WGO - 7,4452; MOS - 2,7812; PO - 7,3824. Para a medição 30 minutos após a manipulação: HPB20% - 9,4014; HPB35% - 8,2914; WGO35% – 7,4736; MOS 35% - 3,3592; PO37,5% - 7,629. Já no tempo 45 minutos após a manipulação: WGO35% - 7,3722; HPB20% - 9,1574; HPB35% - 8,2826; MOS35% - 3,389 e PO37,5% - 7,5264 e para 7 dias obteve-se as médias de: WGO35% - 7,4032; HPB20% - 8,2174; HPB35% - 7,2906; MOS35% 3,0902 e PO37,5% - 7,1964. Aos resultados foram aplicados os testes estatísticos Kruskal-Wallis e Friedman, sendo que o nível de significância máximo assumido foi de 5% (p≤0,05). Os resultados mostraram variações de pH entre todos os tempos e diferenças estatisticamente significativas entre os géis clareadores. O gel clareador White Gold Office 35% mostrou a menor variação de pH no tempos aferidos, ou seja, apresenta maior estabilidade entre os géis avaliados. O gel clareador Mix One Supreme 35% apresentou diferenças estatísticas significativas em relação aos valores de pH dos demais grupos de géis clareadores, mostrando um valor de pH médio ácido (abaixo do valor crítico pH 5,5).pt_BR
dc.description.abstractThis study evaluated the pH of bleaching agents of practice in relation to time after activation. In this study were analyzed five bleaching agents: HP Blue 20% - FGM (HPB20%); HP Blue 35% - FGM (HPB35%); Whitegold Office 35 %- Dentsply (WGO35%); MixOne Supreme – Villevie (MOS35%); Pola Office+ 37,5% -- SDI (PO37,5%). For the measurement of pH, bleaching gels were active and made measurements of pH in the times: early time, thirty minutes, forty-five minutes and seven days. For measurement of pH used a pH meter (DM23 Digimed) calibrated in buffer pH 4,00 and pH 6,86. This calibration was performed on each measure in each of the bleaching gels, in that manipulated three grams of gel was placed in a test tube each. This process was repeated five times for each bleaching agent (n=5). Soon after the manipulation, the average pH measurements: HPB20% -9,3048; HPB35% - 8,4936; WGO - 7,4452; MOS - 2,7812; PO - 7,3824. For measurement thirty minutes after the manipulation: HPB20% - 9,4014; HPB35% - 8,2914; WGO35% – 7,4736; MOS 35% -3,3592; PO37,5% - 7,629. For measurement forty-five minutes after the manipulation: WGO35% - 7,3722; HPB20% - 9,1574; HPB35% - 8,2826; MOS35% - 3,389 e PO37,5% - 7,5264 and for seven days the averages were WGO35% - 7,4032; HPB20% - 8,2174; HPB35% - 7,2906; MOS35% 3,0902 e PO37,5% - 7,1964. Results were applied to statistical tests Kruskal-Wallis and Friedman, and the maximum level of significance adopted was 5% (p ≤ 0.05). The results showed variations in pH between all times and statistically significant differences between the bleaching gels. The whitening gel Office White Gold 35% showed the least change in pH measured in time, in other words, it has greater stability between the gels evaluated. The whitening gel Mix Supreme One 35% showed statistically significant differences in relation to pH values of other groups of bleaching gels, showing an average pH value acid (pH below the critical value 5.5).en
dc.format.mimetypeapplication/pdf
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectDental bleachingen
dc.subjectMateriais odontologicos : Avaliacaopt_BR
dc.subjectHydrogen peroxideen
dc.subjectpHen
dc.titleAvaliação in vitro do ph de géis clareadores de consultório em diferentes tempos após a ativaçãopt_BR
dc.typeTrabalho de conclusão de graduaçãopt_BR
dc.contributor.advisor-coHashizume, Lina Naomipt_BR
dc.identifier.nrb000795181pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentFaculdade de Odontologiapt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2011pt_BR
dc.degree.graduationOdontologiapt_BR
dc.degree.levelgraduaçãopt_BR


Ficheros en el ítem

Thumbnail
   

Este ítem está licenciado en la Creative Commons License

Mostrar el registro sencillo del ítem