Avaliação do processo de eletrodiálise reversa no tratamento de efluentes de refinaria de petróleo
dc.contributor.advisor | Ferreira, Jane Zoppas | pt_BR |
dc.contributor.author | Machado, Mara de Barros | pt_BR |
dc.date.accessioned | 2011-05-11T06:00:39Z | pt_BR |
dc.date.issued | 2008 | pt_BR |
dc.identifier.uri | http://hdl.handle.net/10183/28928 | pt_BR |
dc.description.abstract | Este trabalho teve como objetivo avaliar a aplicação da eletrodiálise reversa no tratamento de efluente final de refinaria para reuso em sistema de resfriamento. O estudo foi conduzido nas instalações da Refinaria Gabriel Passos (REGAP)- MG, com efluente real, proveniente da saída da Estação de Tratamento de Despejos Industriais (E.T.D.I.), e utilizando para os testes uma unidade-piloto de eletrodiálise reversa com capacidade de tratamento de 2 m3/h. A utilização do processo de dessalinização por EDR teve o objetivo de reduzir sólidos totais dissolvidos no efluente de aproximadamente 1.240 mg/L para 310 mg/L, o que equivale a cloretos de 460 mg/L e 100 mg/L respectivamente, para atingir a qualidade requerida para água de make-up da torre de resfriamento da REGAP. Inicialmente foi feita uma avaliação comparativa com o processo de osmose inversa, no qual foi constatada, com o uso da EDR, a maior continuidade operacional, menores problemas de incrustação e menor exigência para o pré-tratamento do efluente. No estudo com a EDR foram realizados testes variando-se a vazão, de 600 a 2000 L/h de produto; voltagem de 200 a 370V e número de estágios. Durante os testes foi realizado o monitoramento operacional e analítico da água de alimentação da EDR, do produto (solução diluída) e do rejeito (concentrado salino), sendo os dados avaliados e correlacionados para determinação da densidade de corrente, taxa hidráulica, eficiência e taxa de remoção de sais. A análise da formação de incrustações e deposições na superfície das membranas levou ao estabelecimento de um procedimento de limpeza química. O estudo foi conduzido de forma a obter a otimização da operação com rendimento necessário na remoção de sólidos dissolvidos, menor custo energético e de manutenção. Após os testes foi selecionada a condição otimizada da unidade piloto: módulo em 2 estágios, vazão de 1,1 m3/h e voltagem de 275V. Para este condição o consumo energético foi de 1,95 KWh/m3 de efluente tratado. Os resultados mostraram a viabilidade técnica-econômica do uso da EDR para remoção de sais de efluente final de refinaria para aplicação em reposição de sistemas de resfriamento. | pt_BR |
dc.description.abstract | This study aimed the evaluation of the application of electrodialysis reversal in final effluent treatment targeting the reuse in cooling towers. The study was done in Gabriel Passos Refinery (REGAP) - MG, with real effluent, from the Industrial Effluent Treatment Station (ETDI), and was held in a pilot plant of electrodialysis reversal with a treatment capacity of 2 m3 / h. The use of the desalination process with EDR target the reduction of total dissolved solids in the effluent of about 1.240 mg / L to 310 mg / L, equivalent to chlorides of 460 mg / L and 100 mg / L respectively, to reach the required quality of make-up water in the REGAP cooling tower. It was originally done a comparative evaluation with reverse osmosis process, another method of membrane desalination. Electrodialysis was selected because of its operating stability, less problems with scaling and fouling, dispensing the use of conditioning chemicals, and the requirement of a simpler pre- treatment The tests with EDR were carried out ranging the product flux for 600 to 2.000 L/h, the voltage for 200 to 370V and the number of hydraulic stages. During the tests were analyzed operational and analytical data in the EDR feed, product (diluted solution) and reject (concentrated solution), being the parameters analyzed and correlated to determine the current density, hydraulic rate, efficiency and salts removal rate. The analysis of fouling and deposition formation on the membranes surface led to an establishment of a chemical cleaning procedure. This study was conducted in order to obtain the operational optimizing with the necessary income to remove dissolved solids, with lower energy cost and maintenance. After the tests was selected the optimum condition for the pilot plant: stack in 2 stages, flow rate of 1.1 m3/h and voltage of 275V. In this condition the power consumption was 1.95 KWh/m3 of treated effluent. The results showed the technical and economic feasibility for the EDR in removing salts from refinery effluents for reuse in make up of cooling systems. | en |
dc.format.mimetype | application/pdf | |
dc.language.iso | por | pt_BR |
dc.rights | Open Access | en |
dc.subject | Electrodialysis | en |
dc.subject | Tratamento de efluentes | pt_BR |
dc.subject | Effluent treatment | en |
dc.subject | Reúso da água | pt_BR |
dc.subject | Water reuse | en |
dc.title | Avaliação do processo de eletrodiálise reversa no tratamento de efluentes de refinaria de petróleo | pt_BR |
dc.type | Dissertação | pt_BR |
dc.identifier.nrb | 000772914 | pt_BR |
dc.degree.grantor | Universidade Federal do Rio Grande do Sul | pt_BR |
dc.degree.department | Escola de Engenharia | pt_BR |
dc.degree.program | Programa de Pós-Graduação em Engenharia de Minas, Metalúrgica e de Materiais | pt_BR |
dc.degree.local | Porto Alegre, BR-RS | pt_BR |
dc.degree.date | 2008 | pt_BR |
dc.degree.level | mestrado | pt_BR |