Mostrar el registro sencillo del ítem

dc.contributor.advisorSó, Marcus Vinicius Reispt_BR
dc.contributor.authorArrué, Thalita Ayrespt_BR
dc.date.accessioned2024-08-15T06:31:18Zpt_BR
dc.date.issued2024pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/277387pt_BR
dc.description.abstractObjetivos: Avaliar o efeito da ativação ultrassônica de sistemas adesivos autocondicionantes (Clearfil SE, Prime & Bond Universal e Single Bond Universal) na penetração intratubular destes adesivos e na resistência de união de pinos de fibra de vidro à dentina radicular através de Microscopia Confocal de Varredura a Laser (MCVL) e teste de push-out. Materiais e métodos: A amostra foi composta de 60 dentes bovinos extraídos, os quais tiveram suas raízes seccionadas e padronizadas. Os canais radiculares foram preparados e tiveram seus terços apicais obturados. Três adesivos autocondicionantes foram selecionados para o estudo (Clearfil SE, Prime & Bond Universal e Single Bond Universal). A amostra foi dividida em seis grupos com 10 raízes. Em três grupos, foi relizado o protocolo adesivo indicado pelo fabricante de cada sistema e, nos demais, foi realizada a ativação ultrassônica do sistema adesivo, sendo 20 segundos de ativação do primer e 10 segundos de ativação do adesivo (sistema Clearfil SE) e 20 segundos de ativação do adesivo nos dois outros grupos. Em todos os dentes, foi realizada a cimentação de pinos de fibra com o cimento RelyX ARC. As raízes tiveram sua porção do pino dividida em três fatias de 2mm de espessura. Para análise da penetração intratubular, as fatias referentes ao terço apical do pino foram submetidas à MCVL e tiveram suas imagens examinadas. Para análise da resistência de união dos pinos de fibra, todas as fatias foram submetidas ao teste de push-out. Para determinação do padrão de falha ocorrido no teste de push-out, todos os cortes foram analisados sob microscópio óptico em aumento de 10x. Dados de resistência de união foram analisados estatisticamente por ANOVA (1 via) e teste post hoc de Tukey. Para comparação dos protocolos padrão e com ativação ultrassônica, foi utilizado teste t de Student. Para a penetração intratubular dos adesivos foi realizada uma análise descritiva das imagens geradas por MCVL de cada grupo estudado. Resultados: A penetração intratubular foi visualmente superior nos grupos submetidos à ativação ultrassônica dos sistemas adesivos. Quanto à resistência de união, não houve diferença entre os terços do canal protético. No protocolo padrão, o adesivo Prime & Bond Universal apresentou menor resistência de união (P<0.05). No protocolo de ativação ultrassônica, o adesivo Clearfil SE apresentou superior resistência de união (P<0.05). Quando comparados os protocolos padrão e com ativação ultrassônica, os adesivos Clearfil SE e Prime & Bond Universal apresentaram maiores valores de resistência de união quando submetidos à ativação ultrassônica (P<0.05). Conclusões: A ativação ultrassônica aumentou a penetração intratubular dos adesivos autocondicionantes e a força de união do Clearfil SE e Prime & Bond Universal. Ativação ultrassônica influenciou na prevalência dos padrões de falha observados após teste de push-out.pt_BR
dc.description.abstractObjectives: To evaluate the effect of ultrasonic activation on self-etch adhesive systems (Clearfil SE, Prime & Bond Universal, and Single Bond Universal) on the dentin tubule penetration of these adhesives and on the bond strength of fiberglass posts to root dentin using confocal laser scanning microscopy (CLSM) and push-out test. Material and methods: Sixty extracted bovine teeth had their roots sectioned and standardized. The root canals were prepared, and their apical thirds were filled. Three self-etching adhesives were selected for this study (Clearfil SE, Prime & Bond Universal, and Single Bond Universal). The sample was divided into six groups with ten roots each. The manufacturer's adhesive protocols were applied in three groups. In three groups, the adhesive systems were ultrasonic activated for 20 seconds on primer, 10 seconds on bond (Clearfil SE system), and 20 seconds on the other systems' adhesives. Fiber posts were cemented with RelyX ARC cement in all roots. The prosthetic portions of the roots were cut into three 2mm thick slices. The images of the apical third of the posts were examined with CLSM to observe dentin tubule penetration. All slices were submitted to a push-out test to obtain the bond strength of fiber posts to root dentin. The failure patterns were analyzed under an optical microscope at 10x magnification. Bond strength values were statistically analyzed using 1-way ANOVA and Tukey's post hoc test. The students' t-test was used to compare the standard and the ultrasonic activation protocols. The dentinal tubule penetration of the adhesives was described after CLSM's image observation and analysis. Results: Adhesive dentin tubule penetration was visually superior in ultrasonic-activated adhesive systems. There was no difference between the thirds of the prosthetic canal's bond strength. In the standard adhesive protocols, the Prime & Bond Universal system presented lower bond strength (P<0.05). In the adhesive ultrasonic activation protocols, the Clearfil SE system presented higher bond strength (P<0.05). Comparing standard and ultrasonic activation protocols, Clearfil SE and Prime & Bond Universal adhesive systems presented higher bond strength values when ultrasonic activated (P<0.05). Conclusions: Ultrasonic activation improved self-etch adhesives dentinal tubule penetration and bond strength of Clearfil SE and Prime & Bond Universal. Ultrasonic activation of self-etch adhesive systems influenced the prevalence of adhesive failure patterns.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectDental pinsen
dc.subjectAdesivos dentináriospt_BR
dc.subjectDental stress analysisen
dc.subjectAnálise do estresse dentáriopt_BR
dc.subjectEndodontiapt_BR
dc.subjectDentin-bonding agentsen
dc.subjectPinos dentáriospt_BR
dc.subjectEndodonticsen
dc.subjectUltrasonicsen
dc.subjectUltrassompt_BR
dc.titleAtivação ultrassônica de diferentes sistemas adesivos autocondicionantes : resistência de união de pinos de fibra de vidro e penetração intratubularpt_BR
dc.title.alternativeUltrasonic activation of different self-etching adhesive systems dentin tubule penetration and push-out bond strength of fiber postsen
dc.typeDissertaçãopt_BR
dc.identifier.nrb001209015pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentFaculdade de Odontologiapt_BR
dc.degree.programPrograma de Pós-Graduação em Odontologiapt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2024pt_BR
dc.degree.levelmestradopt_BR


Ficheros en el ítem

Thumbnail
   

Este ítem está licenciado en la Creative Commons License

Mostrar el registro sencillo del ítem