Efficient analysis of polycyclic aromatic hydrocarbons by dispersive-μ-solid-phase extraction using silica-based nanostructured sorbent phases coupled to gas chromatography-mass spectrometry
dc.contributor.author | Scheid, Camila | pt_BR |
dc.contributor.author | Rodrigues, Wendell de Mello | pt_BR |
dc.contributor.author | Buchner, Silvio | pt_BR |
dc.contributor.author | Benvenutti, Edilson Valmir | pt_BR |
dc.contributor.author | Deon, Monique | pt_BR |
dc.contributor.author | Merib, Josias de Oliveira | pt_BR |
dc.date.accessioned | 2023-12-16T03:26:23Z | pt_BR |
dc.date.issued | 2023 | pt_BR |
dc.identifier.issn | 2772-5820 | pt_BR |
dc.identifier.uri | http://hdl.handle.net/10183/268499 | pt_BR |
dc.description.abstract | In this study, SBA-15 mesoporous silica has been investigated as sorbent phase for the extraction and determi nation of 10 polycyclic aromatic hydrocarbons (PAHs) in environmental water samples for the first time. The extraction step was performed through a dispersive-μ-solid-phase extraction (D-μ-SPE) followed by gas chro matography coupled to mass spectrometry (GC-MS). In particular, the surface of SBA-15 was chemically bonded to different functional groups (aminopropyl, phenyl, octyl and octadecyl), and the extraction efficiency of each sorbent phase was investigated. The sorbent phase was synthesized and characterized by transmission electron microscopy (TEM), Fourier transform infrared spectroscopy (FTIR), N2 sorption analysis (Brunauer–Emmett– Teller), and thermogravimetric analysis (TGA). The optimized extraction conditions consisted of using 2 mg of the sorbent SBA-15/C8, 2 mL of sample, 2 min of vortex, 4 min of stirring in orbital shaker and 1 min of cen trifugation; the desorption step was performed with 25 μL of ACN:acetone (50:50 v/v), vortex for 2 min, 8 min of stirring in orbital shaker and 3 min of centrifugation. The proposed method was validated, with determination coefficients higher than 0.99 for all analytes; LODs and LOQs ranged from 0.15 to 3.03 𝜇g L−1 and from 0.5 to 10.0 𝜇g L−1, respectively; intraday precision ranged from 2.6 to 12.1%; interday precision varied from 4.5 to 25.3%; and accuracy ranged from 92.0 to 112.3 %. This methodology was successfully applied for the analysis of eight groundwater samples from monitoring wells of gas stations in São Paulo. Moreover, according to AGREEp rep metrics, the proposed method can be considered sustainable according to the concepts of green analytical chemistry. | en |
dc.format.mimetype | application/pdf | pt_BR |
dc.language.iso | eng | pt_BR |
dc.relation.ispartof | Advances in Sample Preparation. Amsterdam. Vol. 7 (Aug. 2023), 100070, 9 p. | pt_BR |
dc.rights | Open Access | en |
dc.subject | Mesoporous silica | en |
dc.subject | Sílica | pt_BR |
dc.subject | SBA-15 | en |
dc.subject | Hidrocarbonetos | pt_BR |
dc.subject | Cromatografia gasosa acoplada a espectrômetro de massa | pt_BR |
dc.subject | PAH | en |
dc.subject | Sample preparation | en |
dc.subject | Green analytical chemistry | en |
dc.title | Efficient analysis of polycyclic aromatic hydrocarbons by dispersive-μ-solid-phase extraction using silica-based nanostructured sorbent phases coupled to gas chromatography-mass spectrometry | pt_BR |
dc.type | Artigo de periódico | pt_BR |
dc.identifier.nrb | 001170600 | pt_BR |
dc.type.origin | Estrangeiro | pt_BR |
Files in this item
This item is licensed under a Creative Commons License
-
Journal Articles (39552)Exact and Earth Sciences (6036)