Mostrar el registro sencillo del ítem
Estudo de caso : fissuras em paredes de vedação em alvenaria de blocos cerâmicos
dc.contributor.advisor | Oliveira, Cristiane Sardin Padilla de | pt_BR |
dc.contributor.author | Alves, Nathan Toledo | pt_BR |
dc.date.accessioned | 2022-06-14T04:42:29Z | pt_BR |
dc.date.issued | 2021 | pt_BR |
dc.identifier.uri | http://hdl.handle.net/10183/240207 | pt_BR |
dc.description.abstract | As fissuras caracterizam-se por um tipo manifestação patológica frequente em obras da construção civil. Dependendo da gravidade de risco, sua ocorrência pode afetar o nível de desempenho da edificação reduzindo sua vida útil, caso não sejam feitas as manutenções preventivas ou corretivas adequadas. A fissura geralmente é um alerta (sintoma) de que algo errado está acontecendo com a edificação. Devido à variabilidade e amplitude do tema, esta pesquisa delimitou o estudo à ocorrência de fissuras em paredes de alvenaria não estrutural, ou seja, em paredes de vedação (internas ou externas à edificação) com blocos e tijolos (vazados ou maciços) de concreto ou cerâmica. Foi desenvolvida uma pesquisa não experimental baseada na técnica da observação, adotando como técnicas a inspeção visual e equipamento manual fissurômetro (modelo tipo régua graduada). A pesquisa foi classificada como uma pesquisa de campo e teve como objeto analisar uma edificação multifamiliar de 10 pavimentos localizada na cidade de Porto Alegre/RS. Foi realizado um levantamento das ocorrências e localização das fissuras nas paredes de vedação da edificação com objetivo específico de caracterizá-las, identificar as possíveis causas e sugerir terapias de manutenção, visando eliminar ou estancar o problema. Como resultados foram identificadas 124 fissuras, dentre as causas da ocorrência mais pontuadas se destacou a ocorrência de fissuras por deformação estrutural, seguida das fissuras por concentração de tensões em vãos, aberturas e esquadrias e aquelas ocorridas em locais de instalação de elementos embutidos (tubulações) nas paredes. A pesquisa também apresentou como alternativa mais viável de reparo das fissuras a técnica de recuperação que prevê a dessolidarização das camadas de reboco em relação à base (bloco de vedação). | pt_BR |
dc.description.abstract | Cracks are characterized by a common pathological manifestation in civil construction works. Depending on the severity of the risk, its occurrence can affect the building's performance level, reducing its useful life, if proper preventive or corrective maintenance is not performed. A fissure is usually an alert (symptom) that something is wrong with the building. Due to the variability and breadth of the theme, this research limited the study to the occurrence of cracks in non-structural masonry walls, that is, in sealing walls (internal or external to the building) with concrete or solid blocks and bricks (hollow or solid). ceramics. A non-experimental research was developed based on the observation technique, adopting as techniques the visual inspection and manual fissurometer equipment (graded ruler type model). The research was classified as a field research and had as object to analyze a multifamily building with 10 floors located in the city of Porto Alegre/RS. A survey of the occurrences and location of cracks in the building's sealing walls was carried out with the specific objective of characterizing them, identifying possible causes and suggesting maintenance therapies, in order to eliminate or stop the problem. As a result, 124 cracks were identified, among the most frequent causes of occurrence, the occurrence of cracks due to structural deformation was highlighted, followed by cracks due to stress concentration in spans, openings and frames and those occurring in installation sites of embedded elements (pipes) on the walls. The research also presented as the most viable alternative for repairing cracks the recovery technique that foresees the desolidarization of the plaster layers in relation to the base (sealing block). | en |
dc.format.mimetype | application/pdf | pt_BR |
dc.language.iso | por | pt_BR |
dc.rights | Open Access | en |
dc.subject | Paredes de alvenaria | pt_BR |
dc.subject | Fissure | en |
dc.subject | Blocos cerâmicos | pt_BR |
dc.subject | Sealing masonry | en |
dc.subject | Fissuras (Engenharia) | pt_BR |
dc.subject | Pathological manifestations | en |
dc.subject | Walls | en |
dc.subject | Sealing blocks | en |
dc.title | Estudo de caso : fissuras em paredes de vedação em alvenaria de blocos cerâmicos | pt_BR |
dc.type | Trabalho de conclusão de graduação | pt_BR |
dc.identifier.nrb | 001140016 | pt_BR |
dc.degree.grantor | Universidade Federal do Rio Grande do Sul | pt_BR |
dc.degree.department | Escola de Engenharia | pt_BR |
dc.degree.local | Porto Alegre, BR-RS | pt_BR |
dc.degree.graduation | Engenharia Civil | pt_BR |
dc.degree.level | graduação | pt_BR |