Resistência do esmalte adjacente à restauração com material alkasite frente a desafio erosivo – um estudo in vitro
View/ Open
Date
2019Author
Advisor
Academic level
Graduation
Subject
Abstract in Portuguese (Brasil)
Objetivo: objetivo do presente estudo foi comparar o potencial de proteção frente ao desafio erosivo de dentes bovinos restaurados com Cention N® com outros materiais restauradores convencionais. Materiais e Métodos: Foram confeccionados blocos de esmalte padronizados e polidos de incisivos bovinos extraídos (8mm de diâmetro e 2 mm de espessura). Os espécimes foram submetidos a testes de microdureza Knoop em um microdurômetro (HMV 2, Shimadzu, Tokyo, Japan) antes de serem preparados e restaurad ...
Objetivo: objetivo do presente estudo foi comparar o potencial de proteção frente ao desafio erosivo de dentes bovinos restaurados com Cention N® com outros materiais restauradores convencionais. Materiais e Métodos: Foram confeccionados blocos de esmalte padronizados e polidos de incisivos bovinos extraídos (8mm de diâmetro e 2 mm de espessura). Os espécimes foram submetidos a testes de microdureza Knoop em um microdurômetro (HMV 2, Shimadzu, Tokyo, Japan) antes de serem preparados e restaurados para definição da microdureza inicial e seleção da amostra. Após, os espécimes foram restaurados com 4 diferentes materiais restauradores: Resina bulk fill, Ionômero de Vidro Riva Self e Light-Cure e Cention N® seguindo uma cavidade padronizada de 1mm de diâmetro por 1,8 mm de profundidade. Os blocos foram preparados, restaurados com os 4 diferentes materiais e receberam acabamento e polimento segundo indicações dos fabricantes. O desafio erosivo foi realizado imergindo os blocos sob agitação mecânica em solução de ácido cítrico 1% por 10 minutos. Testes de microdureza Knoop superficial foram novamente realizados a fim de determinar a microdureza pós experimento. Os dados foram analisados estatisticamente utilizando-se teste T de Student para comparar as médias de microdureza iniciais entre os diferentes grupos. A comparação entre os valores iniciais e finais de microdureza dentro de cada grupo foi realizada utilizando-se teste T Pareado. A diferença entre a microdureza inicial e final (Δ dureza) entre os diferentes grupos foi realizada utilizando-se ANOVA de uma via, seguida de teste a posteriori de Dunnett. O nível de significância adotado foi de 5% e o pacote estatístico utilizado foi SPSS para Windows® (IBM SPP Statistics 20). Resultados: Não foi encontrada diferença estatisticamente significativa (p>0,05) com relação à microdureza inicial quando comparados os blocos dos diferentes grupos (média 316,65 ±14,30). Quando comparada a microdureza superficial final com a inicial dentro de cada grupo, houve diferença estatística (p<0,05). Os valores de Δ de microdureza pós desafio erosivo entre os diferentes materiais restauradores utilizados não apresentaram diferença estatisticamente significativa (p= 0,26). Conclusão: Os materiais restauradores liberadores de íons testados, entre eles o Cention N®, não são capazes de atuar de forma significativa na prevenção da perda mineral em desafio erosivo in vitro ...
Abstract
Objective: The aim of the present study was to compare the potential for protection after erosive challenge of Cention N® in restored bovine teeth with other conventional restorative materials. Materials and Methods: Standardized and polished enamel blocks of extracted bovine incisors (8mm in diameter and 2mm in thickness) were made. The specimens were subjected to Knoop microhardness tests on a microhardness meter (HMV 2, Shimadzu, Tokyo, Japan) before being prepared and restored for initial m ...
Objective: The aim of the present study was to compare the potential for protection after erosive challenge of Cention N® in restored bovine teeth with other conventional restorative materials. Materials and Methods: Standardized and polished enamel blocks of extracted bovine incisors (8mm in diameter and 2mm in thickness) were made. The specimens were subjected to Knoop microhardness tests on a microhardness meter (HMV 2, Shimadzu, Tokyo, Japan) before being prepared and restored for initial microhardness definition and sample selection. Afterwards, the specimens were restored with 4 different restorative materials: bulk fill resin, Riva Self and Light-Cure and Cention N® Glass Ionomer following a standardized cavity of 1mm diameter by 1.8mm depth. The blocks were prepared, restored with the 4 different materials and received finishing and polishing according to indications of the manufacturers. The erosive challenge was accomplished by immersing the blocks under mechanical agitation in 1% citric acid solution for 10 minutes. Surface Knoop microhardness tests were again performed to determine the post-experiment microhardness. Data were statistically analyzed using Student's t-test to compare initial microhardness averages between different groups. The comparison between the initial and final microhardness values within each group was performed using the paired t test. The difference between initial and final microhardness (Δ hardness) between the different groups was performed using one-way ANOVA, followed by Dunnett's a posteriori test. The significance level adopted was 5% and the statistical package used was SPSS for Windows® (IBM SPP Statistics 20). Results: There was no statistically significant difference (p> 0.05) in relation to the initial microhardness when comparing the blocks of the different groups (mean 316.65 ± 14.30). When comparing the final and initial microhardness within each group, there was a statistical difference (p <0.05). The microhardness Δ values after erosion challenge between the different restorative materials used did not present statistically significant difference (p = 0.26). Conclusion: The tested ion-releasing restorative materials, including Cention N®, are not able to act significantly in preventing erosion challenge mineral loss in vitro ...
Institution
Universidade Federal do Rio Grande do Sul. Faculdade de Odontologia. Curso de Odontologia.
Collections
This item is licensed under a Creative Commons License