Mostrar registro simples

dc.contributor.authorMattiuzi, Camila Dalla Portapt_BR
dc.contributor.authorKirchheim, Roberto Eduardopt_BR
dc.contributor.authorCollischonn, Walterpt_BR
dc.contributor.authorFan, Fernando Mainardipt_BR
dc.date.accessioned2022-04-06T04:44:47Zpt_BR
dc.date.issued2015pt_BR
dc.identifier.issn0101-7004pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/236573pt_BR
dc.description.abstractEste estudo se propõe a estimar as taxas de recarga subterrânea na Bacia Hidrográfica do Rio Ibicuí, localizada no Estado do Rio Grande do Sul, a partir da utilização do método de separação do escoamento de base. O principal aquífero da Bacia é o Sistema Aquífero Guarani (SAG), nas suas áreas de confinamento (Oeste) e afloramento (Central). A separação do escoamento de base foi realizada por meio do filtro numérico de Eckhardt (2005) com dados de séries históricas de vazão disponibilizados pela Agência Nacional das Águas. As estimativas de recarga foram comparadas com as características geológicas, hidrogeológicas e pedológicas encontradas na área de estudo. As taxas de recarga variaram de 88 mm/ano a 378,7 mm/ano (13% a 47%, respectivamente da precipitação efetiva nas sub-bacias, e 6% a 21% da precipitação total). Os resultados mostraram que as maiores taxas de recargaocorreram nas unidades geológicas com transmissividades mais elevadas e solos mais permeáveis, e também com precipitações médias mais elevadas. Por outro lado, as sub-bacias com baixas taxas de recarga apresentaram unidades geológicas permeáveis e unidades cristalinas impermeáveis, solos com altos teores de argila e precipitações médias reduzidas.pt_BR
dc.description.abstractThis study aims to estimate the groundwater recharge rates in the Ibicuí Watershed, in the state of Rio Grande do Sul, using baseflow separation method. The watershed’s main aquifer is the Guarani Aquifer System, in its confined areas (West) and outcrop (Central). The baseflow separation was made with the Eckhardt (2005) numerical filter, with historical streamflow data released by the National Water Agency. The recharge estimates were compared with the geological, hydrogeological and soil found in the study area. Recharge rates ranged from 88 mm/year to 378.7 mm/year (13% and 47% respectively of the effective precipitation in the sub-watersheds, and 6% to 21% of total precipitation). The results showed that the higher recharge rates were found in the geological units with higher transmissivity and more permeable soils, and with higher average precipitation. On the other hand, sub-watersheds with low recharge rates showed permeable geologic units and crystal units, soils with high clay content and low average precipitation.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.relation.ispartofÁguas subterrâneas (São Paulo. 1978). Vol. 29, n. 3 (2015), p. 285-300pt_BR
dc.rightsOpen Accessen
dc.subjectBase flowen
dc.subjectRecarga aquíferapt_BR
dc.subjectEckhardt’s filteren
dc.subjectFiltro de Eckhardtpt_BR
dc.subjectEscoamentopt_BR
dc.subjectAquifer rechargeen
dc.subjectIbicuí, Rio, Bacia do (RS)pt_BR
dc.titleEstimativa de recarga subterrânea a partir da separação do escoamento de base na bacia hidrográfica do rio Ibicuí (América do Sul)pt_BR
dc.title.alternativeEstimating recharge rates with baseflow separation in the Ibicuí watershed (south America) en
dc.typeArtigo de periódicopt_BR
dc.identifier.nrb000992083pt_BR
dc.type.originNacionalpt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples