dc.description.abstractO rolete de operador de porta é responsável por garantir a abertura simultânea da porta de pavimento e da cabina do elevador. Esse trabalho analisa a causa raiz da quebra prematura deles. Durante o ano de 2021, a troca desse material cresceu exponencialmente se comparado com os anos anteriores. Em uma obra na região norte do país, onde foram substituídos todos os roletes devido a sua falha, foi verificada a completa quebra da parte externa de borracha, separando-a da parte interna de nylon. Através da análise de possíveis causas, com o auxílio do diagrama de Ishikawa, observou-se o fato de que entre anos anteriores e atualmente, nenhuma modificação na operação ou instalação do produto havia sido realizada. Dessa forma, entende-se que a causa é o próprio componente. A partir de uma comparação entre um rolete de 2019 e um novo observou-se a presença de cavidades na parte externa do mesmo, especificamente onde a ligação mecânica é feita entre as duas partes poliméricas. Concluiu-se que a presença das cavidades ocorreu devido a um problema no processo de injeção do material, o que levou à realização das devidas alterações no processo de fabricação para mitigar o problema encontrado em diversos elevadores espalhados pelo Brasil.pt_BR
dc.description.abstractA door operator rollers is responsible for ensuring the simultaneous opening of the floor door and the elevator cabin. This work analyzes the root cause of their premature breakage. During the year 2021, the exchange of this material grew exponentially compared to previous years. In a job site in the northern region of the country, where all the rollers were replaced due to their failure, the complete breakage of the rubber outer part was verified, separating it from the nylon inner part. Through the analysis of possible causes, with the help of the Ishikawa diagram, it was observed that between previous years and currently, no modification in the handling or installation of the product had been carried out. Thus, it is understood that the cause is the component itself. From a comparison between a 2019 roller and a new one, the presence of cavities on the outside of it was observed, specifically where the mechanical connection is made between the two polymeric parts. It was concluded that the presence of cavities occurred due to a problem in the material injection process, which led to the necessary changes in the manufacturing process to mitigate the problem found in several elevators throughout Brazil.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectElevatoren
dc.subjectElevadorespt_BR
dc.subjectDetecção de falhaspt_BR
dc.subjectRolleren
dc.subjectDoor operatoren
dc.titleAvaliação da falha catastrófica prematura de roletes de abertura de porta de pavimento de elevadores elétricospt_BR
dc.typeTrabalho de conclusão de graduaçãopt_BR
dc.identifier.nrb001134845pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentEscola de Engenhariapt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2021pt_BR
dc.degree.graduationEngenharia Mecânicapt_BR
dc.degree.levelgraduaçãopt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples