Mostrar registro simples

dc.contributor.authorFadel, Amanda Wajnbergpt_BR
dc.contributor.authorDornelles, Fernandopt_BR
dc.date.accessioned2021-08-26T04:09:04Zpt_BR
dc.date.issued2015pt_BR
dc.identifier.issn1414-381Xpt_BR
dc.identifier.urihttp://hdl.handle.net/10183/226160pt_BR
dc.description.abstractO A destinação de efluentes sanitários à rede pluvial é uma constante no Brasil. Tendo em vista a presença anterior do sistema pluvial ao separador absoluto, esta era a alternativa para o afastamento do esgoto cloacal das zonas urbanizadas. Após, com as iniciativas de integralização das redes separadoras abso- lutas, discute-se alternativas para a universalização da coleta de efluentes sanitários. Este trabalho propôs-se a analisar a resposta de uma bacia quando da interceptação das cargas sanitárias presentes no sistema pluvial por meio de coleta de tempo seco. As análises foram feitas com base no modelo chuva-vazão SCS-Hidrograma Unitário Triangular, considerando os dados pluviométricos e características da bacia hidrográfica e do esgoto sanitário da região. Jun- tamente, utilizou-se de séries sintéticas de precipitação que, inseridas no modelo desenvolvido, auxiliaram na obtenção dos resultados. Foi adotada a bacia hidrográfica do Arroio Capivara, na Zona Sul de Porto Alegre, para aplicação da metodologia. O intuito deste estudo foi comparar o total de carga estimada em termos de DBO lançada no corpo receptor com e sem o sistema de interceptação proposto. Para isto, foram idealizados quatro cenários, com a variação da vazão de interceptação e da urbanização (representada pelo parâmetro CN), chegando a valores de aproximadamente 85% de desvio da carga de efluentes.pt_BR
dc.description.abstractDisposal of sanitary sewage into the storm drainage network is a common practice in Brazil. As the storm drain system was commonly built before the sanitary sewers, this was the alternative to remove foul sewage from the urban areas. Afterwards, with the rise of separate sewage networks, alternatives to uni- versal collection of sewage are being discussed. This paper aims to analyze the response of a watershed when intercepting sewage discharges in storm drainage networks, through collection in dry weather conditions. The analysis was based on the SCS-Triangular Unit Hydrograph rainfall-runoff model, considering the rainfall data and watershed and sewage characteristics in the region. In addition, synthetic precipitation series were used to obtain better results. The Arroio Capivara watershed basin (in Porto Alegre city) was chosen to apply this methodology. The aim of this study is to compare the total BOD estimated discharge in the receiving water body with and without the proposed interception system. For this, four scenarios were modeled, varying the flow interception and the level of urbanization (represented by the CN parameter), obtaining values of approximately 85% sewage diverted.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.relation.ispartofRbrh : revista brasileira de recursos hídricos. Porto Alegre, RS. Vol. 20, n. 4 (out./dez. 2015), p. 970-979pt_BR
dc.rightsOpen Accessen
dc.subjectEsgoto sanitáriopt_BR
dc.subjectCombined sewage systemen
dc.subjectFlow interceptionen
dc.subjectInterceptaçãopt_BR
dc.subjectSistemas de esgoto combinadopt_BR
dc.subjectSewage diversion during dry weatheren
dc.subjectEsgoto pluvialpt_BR
dc.titleEficiência da interceptação de esgoto sanitário em rede pluvial na bacia do arroio Capivara - Porto Alegre/RSpt_BR
dc.title.alternativeEfficiency of foul sewage diversion into a storm drainage system in the arroio Capivara watershed basin - Porto Alegre/RS en
dc.typeArtigo de periódicopt_BR
dc.identifier.nrb000981867pt_BR
dc.type.originNacionalpt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples