Show simple item record

dc.contributor.authorTravessas, Juliana Andréa Corrêapt_BR
dc.contributor.authorMahl, Célia Regina Winckpt_BR
dc.contributor.authorFontanella, Vania Regina Camargopt_BR
dc.date.accessioned2020-12-28T04:15:27Zpt_BR
dc.date.issued2004pt_BR
dc.identifier.issn0566-1854pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/216925pt_BR
dc.description.abstractO objetivo deste estudo foi avaliar o comportamento de quatro filmes periapicais da Kodak ® (Ultra-Speed, Insight, Dental Intraoral D-Speed e Dental Intraoral E-Speed) quanto à densidade radiográfica digital. Para a realização do experimento foi selecionada a região de molares inferiores de uma mandíbula humana macerada. Para simular os tecidos moles foi interposta uma placa de cera utilidade entre a fonte de raios X e o espécime.. Assim, foram obtidas 20 radiografias com cada um dos tipos de filmes, utilizando-se dois aparelhos de raios X de diferentes quilovoltagens ( 50 e 70) e com dois tempos dc exposição (0,3 e 0,5 s). Todas as 80 radiografias resultantes foram processadas pelo método temperatura-tempo. As imagens foram digitalizadas e suas densidades foram medidas no programa ImageTool® v.3.0 (UTHSCSA, San Antonio, Texas). Os resultados foram submetidos à Análise de Variância, complementada pelo teste de Comparações Múltiplas de Tukey, ao nível dc significância de 5%. Foram encontradas diferenças significativas entre as densidades dos filmes Dental Intraoral D-Speed e Ultra-Speed, ambos de velocidade D, e Dental Intraoral E-Speed e Insight, ambos de velocidade E, quando processados manualmente.pt_BR
dc.description.abstractThe aim of this study was to evaluate the behavior of four Kodak's® periapical films, namely Ultra-Speed , Insight, Dental lntraoral D-Speed, end Dental Intraoral E-Speed, regarding Radiographic Digital Density. For this purpose 80 images (20 with each film) were taken from the lower molar region of a human dry mandible, using wax simulation soft tissues. The o X-ray equipments were used (5O kV and 70 kV) and two exposure times were considered (0,3s and 0,5s). The films were processed by the time-temperature method. The resulting images were digitized and their Digital Radiographic Densities were obtained by means of the software ImageTool® v. 3.0 (UTHSCSA, San Antonio, Texas). The results were submited to ANOVA statistical analysis complemented by the Tukey's multiple comparison test (p=0,05). Statistically significant differences were found between Ultra-Speed and Dental Intraoral D-Speed and insight and Dental Intraoral E-Speed.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.relation.ispartofRevista da Faculdade de Odontologia de Porto Alegre. Porto Alegre. Vol. 45, n. 2 (dez. 2004), p. 17-20pt_BR
dc.rightsOpen Accessen
dc.subjectDensityen
dc.subjectRadiografia bucal : Filmespt_BR
dc.subjectRadiografia computadorizadapt_BR
dc.subjectRadiographic filmen
dc.subjectQuality controlen
dc.titleAvaliação da densidade radiográfica digital de quatro filmes periapicaispt_BR
dc.title.alternativeEvaluation of radiographic digital densiíy of four periapical films en
dc.typeArtigo de periódicopt_BR
dc.identifier.nrb000474695pt_BR
dc.type.originNacionalpt_BR


Files in this item

Thumbnail
   

This item is licensed under a Creative Commons License

Show simple item record