Mostrar el registro sencillo del ítem
LC-UV method to assay raloxifene hydrochloride in rat plasma and its application to a pharmacokinetic study
dc.contributor.author | Fontana, Márcia Camponogara | pt_BR |
dc.contributor.author | Laureano, João Victor | pt_BR |
dc.contributor.author | Forgiarini, Betielli Gonçalves | pt_BR |
dc.contributor.author | Chaves, Paula dos Santos | pt_BR |
dc.contributor.author | Araújo, Bibiana Verlindo de | pt_BR |
dc.contributor.author | Beck, Ruy Carlos Ruver | pt_BR |
dc.date.accessioned | 2020-01-16T04:08:30Z | pt_BR |
dc.date.issued | 2019 | pt_BR |
dc.identifier.issn | 1984-8250 | pt_BR |
dc.identifier.uri | http://hdl.handle.net/10183/204332 | pt_BR |
dc.description.abstract | A specific, precise, and accurate LC-UV method was developed and validated to assay raloxifene hydrochloride in rat plasma. Raloxifene was analyzed after liquid-liquid extraction and quantified by reversed phase liquid chromatography (C18 column) using acetonitrile and ammonium acetate buffer 0.05 M (pH 4.0) as mobile phase at a flow rate of 1 mL.min-1 and UV detection at 287 nm. Retention times of raloxifene and internal standard (dexamethasone) were approximately 11 min and 14 min, respectively. Linearity was checked for a concentration range between 25 ng.mL-1 and 1000 ng.mL-1. Intra- and inter-day precision had relative standard deviation lower than 10% and 15%, respectively. Recovery from plasma was higher than 90%. Accuracy values were 98.21%, 99.70%, and 102.70% for lower, medium, and upper limits of quantification, respectively. Limit of quantification was 25 ng.mL-1. Drug stability was analyzed at room temperature using plasma kept in a freezer at -80 °C for 45 days after processing for 6 h and three freeze-thaw cycles. The advantages of the method developed include stability under different conditions and low limit of quantification. Its applicability was confirmed by the analysis of raloxifene levels in plasma samples in a designed pharmacokinetic study in rats after intravenous administration (5 mg.kg-1). | en |
dc.format.mimetype | application/pdf | pt_BR |
dc.language.iso | eng | pt_BR |
dc.relation.ispartof | Brazilian journal of pharmaceutical sciences. São Paulo. Vol. 55 (2019), e18052, [6 p.] | pt_BR |
dc.rights | Open Access | en |
dc.subject | Raloxifene/pharmacokinetic | en |
dc.subject | Farmácia | pt_BR |
dc.subject | Liquid chromatography | en |
dc.subject | Cloridrato de raloxifeno | pt_BR |
dc.subject | Plasma | en |
dc.subject | Cromatografia líquida | pt_BR |
dc.subject | Plasma | pt_BR |
dc.subject | Bioavailability | en |
dc.subject | Disponibilidade biológica | pt_BR |
dc.title | LC-UV method to assay raloxifene hydrochloride in rat plasma and its application to a pharmacokinetic study | pt_BR |
dc.type | Artigo de periódico | pt_BR |
dc.identifier.nrb | 001109287 | pt_BR |
dc.type.origin | Nacional | pt_BR |
Ficheros en el ítem
Este ítem está licenciado en la Creative Commons License
-
Artículos de Periódicos (39774)Ciencias de la Salud (10633)