Mostrar registro simples

dc.contributor.authorRoehe, Paulo Michelpt_BR
dc.contributor.authorSchaefer, Rejanept_BR
dc.contributor.authorPereira, Alexandre da Silvapt_BR
dc.date.accessioned2010-04-16T09:11:35Zpt_BR
dc.date.issued2002pt_BR
dc.identifier.issn1678-0345pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/19782pt_BR
dc.description.abstractO diagnóstico laboratorial da raiva utiliza uma metodologia padronizada, baseada essencialmente no método de imunofluorescência direta, ou “direct fluorescent antibody test” (DFAT). No presente estudo foram reavaliadas algumas variáveis do DFAT, incluindo a duração do tempo de fixação das lâminas com impressões de tecido nervoso, duração das incubações de pré-adsorção do conjugado com as suspensões de tecido nervoso de camundongos infectados (IMB) ou não infectados (NMB) e a duração do período de incubação destas misturas sobre as lâminas com as impressões fixadas. A combinação que proporcionou maior eficácia à DFAT foi obtida com a fixação das lâminas com impressões de tecido nervoso em acetona a -20 oC por 30 minutos, pré-adsorção do conjugado com suspensões de NMB e IMB por 60 minutos a 37oC e subseqüente incubação dessas misturas sobre as impressões por 2 horas a 37oC. Estas alterações permitiram a obtenção de uma fluorescência de intensidade sensivelmente maior que a obtida com a metodologia padrão recomendada, aliada a uma completa inibição da fluorescência sobre os controles.pt_BR
dc.description.abstractRabies diagnosis follows a standardized methodology, where the direct fluorescent antibody test (DFAT) plays an essential role. Optimization of DFAT procedures may improve sensitivity and specificity of the test. In the present study, some of the variables of DFAT were reassessed, such as the duration of acetone fixation of brain impressions on slides, incubation of the pre-adsorbing mixtures of conjugate and infected (IMB) and uninfected mouse brain suspensions (NMB), as well as the length of incubation of the pre-adsorbing mixtures on fixed brain impressions. The combination that provided the greatest efficacy at DFAT was attained when slides were fixed for 30 minutes in acetone at -20 oC, the pre-adsorbing conjugate and NMB/ IMB suspensions were incubated for 60 minutes at 37 oC and subsequently layered onto impressions for 2 hours at 37oC. These modifications provided a more intense fluorescent reaction, together with a complete inhibition of fluorescence on the control impressions, when compared to the standard recommended procedure.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.relation.ispartofActa sientiae veterinariae. Porto Alegre, RS. Vol. 30, n. 1 (2002), pub. 527, p. 53-57.pt_BR
dc.rightsOpen Accessen
dc.subjectRabiesen
dc.subjectVirologiapt_BR
dc.subjectImunofluorescênciapt_BR
dc.subjectDiagnosisen
dc.subjectRaivapt_BR
dc.subjectImmunofluorescenceen
dc.subjectDiagnósticopt_BR
dc.subjectDFATen
dc.titleOtimização da imunofluorescência direta para diagnóstico de raivapt_BR
dc.title.alternativeOptimization of the direct fluorescent antibody test for rabies diagnosis en
dc.typeArtigo de periódicopt_BR
dc.identifier.nrb000413578pt_BR
dc.type.originNacionalpt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples