Mostrar el registro sencillo del ítem

dc.contributor.authorJacondino, Luiza Rodegheript_BR
dc.contributor.authorGonçalves, Andressa Silveirapt_BR
dc.contributor.authorRivero, Beatriz Riet Corrêapt_BR
dc.contributor.authorOberst, Eneder Rosanapt_BR
dc.contributor.authorSilva, Marcos Kipper dapt_BR
dc.contributor.authorBirgel, Daniela Beckerpt_BR
dc.contributor.authorBirgel Junior, Eduardo Harrypt_BR
dc.contributor.authorRaimondo, Raquel Fraga e Silvapt_BR
dc.date.accessioned2019-07-11T02:35:19Zpt_BR
dc.date.issued2019pt_BR
dc.identifier.issn0102-0935pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/196790pt_BR
dc.description.abstractAtualmente o uso de sensores portáteis para mensuração de corpos cetônicos está padronizado e difundido na rotina clínica, contudo estudos em ovinos são escassos. Assim, a presente pesquisa objetivou avaliar a acurácia dos sensores portáteis de uso humano e de uso veterinário para a determinação de beta-hidroxibutirato (BHB) em ovelhas no final da gestação e no pós-parto recente. Foram utilizadas 37 amostras de sangue provenientes de nove ovelhas mestiças Corriedale. A determinação bioquímica de BHB no soro, considerada como o padrão-ouro, foi realizada utilizando-se metodologia enzimática colorimétrica. A média obtida na bioquímica sérica foi de 0,497mmol/L; no sensor de uso humano, a média foi igual a 0,537mmol/L, enquanto no sensor de uso veterinário foi de 0,751mmol/L. Foi verificada alta correlação entre o dosímetro de uso humano e o padrão-ouro (r=0,93, P<0,001). A média do aparelho de uso veterinário diferiu das demais (51%; P<0,05), superestimando os resultados em ovelhas. As medições obtidas no aparelho veterinário também apresentaram menor precisão e veracidade. Concluiu-se que o sensor portátil de uso humano é mais acurado e mais preciso no diagnóstico precoce de toxemia da gestação em ovelhas.pt
dc.description.abstractCurrently the use of portable sensors for measuring ketone bodies is standardized and diffused in the clinical routine, however, studies in sheep are scarce. Therefore, the present study aimed to evaluate the accuracy of the human portable sensor and the veterinary portable sensor for the determination of beta-hydroxybutyrate (BHB) in sheep at the end of gestation and postpartum. We used 37 samples of blood from nine crossbred Corriedale sheep. Biochemical determination of serum BHB, considered gold standard, was performed using colorimetric enzymatic methodology. The mean serum biochemistry was 0.497mmol/L, in the human sensor the mean was 0.537mmol/L, while in the veterinary sensor it was 0.751mmol/L. A high correlation was verified between the dosimeter for human use and the gold standard (r= 0.93, P< 0.001). The mean of the veterinary apparatus differed from the others, being 51% (P< 0,05), higher than the standard, that is, it was less accurate and had lower veracity, overestimating the results in sheep. It was concluded that the portable sensor for human use is more accurate and accurate in the early diagnosis of toxemia of pregnancy in sheep.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.relation.ispartofArquivo brasileiro de medicina veterinária e zootecnia. Belo Horizonte. Vol. 71, no. 3 (May/June 2019), p. 857-862pt_BR
dc.rightsOpen Accessen
dc.subjectKetosisen
dc.subjectAcurácia dos dadospt_BR
dc.subjectPregnancy toxemiaen
dc.subjectInstrumentos de mediçãopt_BR
dc.subjectAccuracyen
dc.subjectBeta-hidroxibutiratopt_BR
dc.subjectDiagnosisen
dc.subjectToxemias gravídicaspt_BR
dc.subjectOvinospt_BR
dc.titleComparação de métodos para avaliação de beta-hidroxibutirato em ovelhaspt_BR
dc.title.alternativeComparison of methods for evaluation of beta-hydroxybutyrate in ewes en
dc.typeArtigo de periódicopt_BR
dc.identifier.nrb001097021pt_BR
dc.type.originNacionalpt_BR


Ficheros en el ítem

Thumbnail
   

Este ítem está licenciado en la Creative Commons License

Mostrar el registro sencillo del ítem