Influência da rugosidade gerada pelo tratamento superficial do substrato de concreto na aderência do revestimento de argamassa
dc.contributor.advisor | Masuero, Angela Borges | pt_BR |
dc.contributor.author | Pretto, Márcia Elisa Jacondino | pt_BR |
dc.date.accessioned | 2010-01-29T04:16:03Z | pt_BR |
dc.date.issued | 2007 | pt_BR |
dc.identifier.uri | http://hdl.handle.net/10183/18425 | pt_BR |
dc.description.abstract | O maior uso do concreto de alta resistência, o uso de desmoldante e/ou o emprego de fôrmas plastificadas são fatores que cada vez mais contribuem para a superfície do concreto tornar-se lisa e de baixa porosidade superficial. Dessa forma, há prejuízo da absorção capilar que deve existir na camada superficial da base, de modo a permitir a penetração e a ancoragem dos produtos de hidratação da argamassa de revestimento no interior do substrato, garantindo a ancoragem mecânica. Neste sentido, a presente dissertação é resultado de um trabalho experimental realizado para investigar a influência da rugosidade gerada pelos tratamentos superficiais realizados nos substratos de concreto, com ou sem desmoldante, tais como lavagem por hidrojateamento, escovação, lixamento, apicoamento e uso de retardador de pega de superfície, na aderência do revestimento de argamassa. Para atender os objetivos propostos, moldaram-se prismas de concreto em três níveis de resistência fc28 (25 MPa, 35 MPa e 45 MPa), cujas superfícies foram tratadas e preparadas com chapisco convencional, traço 1:3 e chapisco adesivo. A argamassa de revestimento empregada foi industrializada. O programa experimental envolveu primeiramente a caracterização inicial dos materiais utilizados na confecção dos prismas de concreto, bem como das argamassas empregadas. Como caracterização dos substratos tratados, foram realizados ensaios para caracterizar a superfície, quanto à rugosidade e sucção capilar. A rugosidade foi avaliada em duas dimensões, através de perfis, de acordo com parâmetros normalizados, e também em três dimensões, através da superfície específica. Após o tratamento dos substratos, foi feita a aplicação da camada de chapisco, convencional e industrializado, e posteriormente, a aplicação da argamassa de revestimento, em camada única. Por fim, os revestimentos aplicados foram avaliados quanto à resistência de aderência e extensão de aderência. Com os resultados obtidos, concluiu-se que o uso do desmoldante prejudica a sucção capilar de substratos de concreto de fc28 igual ou inferior a 35 MPa. Conclui-se também que concretos de fc28 igual a 25 MPa possuem porosidade suficiente para garantir ancoragem mecânica, não necessitando de tratamento superficial, assim como quando se utiliza chapisco industrializado em qualquer concreto. Ao se utilizar chapisco convencional, a resistência de aderência aumenta a medida que se aumenta a rugosidade da superfície. | pt_BR |
dc.description.abstract | The widespread use of high resistance concrete , the use of lubricant and the employment of plastic-coated molds are factors that more and more contribute to the flat surface and low porosity of the concrete. Thus, there is damage of the capillary absorption that should exist in the substrate superficial layer, in order to allow the entrance and the anchorage of the hydration products of the coating mortar inside the substrate, guaranteeing the mechanical anchorage. In this way, the present dissertation resulted as experimental work realized to investigate the influence of the rugosity generated by the superficial treatments in the concrete substrate, with or without lubricant, such as wash with high pressure water jetting, brushing, grinding, milling and use of retarder of surface, in the adherence of the coating mortars. To reach the proposed objectives, concrete prisms were molded in three levels of resistance fc28 (25 MPa, 35 MPa and 45MPa), its surfaces were treated and prepared with conventional slurry mortar and adhesive slurry mortar. The coating mortar was industrialized. The experimental program involved the initial characterization of the materials used in concrete and mortars. To characterize the concrete surface tests were realized to characterize the rugosity and sorptivity. The rugosity was evaluated in two dimensions, through profiles, in accordance with parameters normalized, and also in three dimensions, through specific surface. Slurry mortar industrialized and conventional was applied after the substrate treatment, and the covering mortar was applied after in only one layer. Finally, the coverings applied were evaluated on the bond strength and adherence extension. The results obtained showed us that the use of the lubricant damages capillary suction on the concrete substrate 35MPa. Concretes 25MPa possess enough porosity to guarantee mechanical anchorage, not needing superficial treatment, as well when slurry mortar industrialized is used in any concrete. The resistance of adherence increases when the rugosity of the surface increases. | en |
dc.format.mimetype | application/pdf | |
dc.language.iso | por | pt_BR |
dc.rights | Open Access | en |
dc.subject | Argamassa de revestimento | pt_BR |
dc.subject | Mortar | en |
dc.subject | Ensaios de materiais | pt_BR |
dc.subject | Slurry mortar | en |
dc.subject | Concrete | en |
dc.subject | Concreto | pt_BR |
dc.subject | Lubricant | en |
dc.subject | Substrate treatment | en |
dc.subject | Rugosity | en |
dc.subject | Sorptivity | en |
dc.title | Influência da rugosidade gerada pelo tratamento superficial do substrato de concreto na aderência do revestimento de argamassa | pt_BR |
dc.title.alternative | Influence of the rugosity produced by concrete substrate treatment in the adherence of mortar coverings | en |
dc.type | Dissertação | pt_BR |
dc.identifier.nrb | 000728422 | pt_BR |
dc.degree.grantor | Universidade Federal do Rio Grande do Sul | pt_BR |
dc.degree.department | Escola de Engenharia | pt_BR |
dc.degree.program | Programa de Pós-Graduação em Engenharia Civil | pt_BR |
dc.degree.local | Porto Alegre, BR-RS | pt_BR |
dc.degree.date | 2007 | pt_BR |
dc.degree.level | mestrado | pt_BR |
Files in this item
This item is licensed under a Creative Commons License
-
Engineering (7412)Civil Engineering (1183)