Mostrar registro simples

dc.contributor.advisorPereira, Carlos Eduardopt_BR
dc.contributor.authorSoto, Viyils Sangregoriopt_BR
dc.date.accessioned2017-07-06T02:44:44Zpt_BR
dc.date.issued2016pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/163728pt_BR
dc.description.abstractEste trabalho analisa o uso do protocolo WirelessHART para a implementação de sistemas de controle em laço fechado. São discutidas possíveis arquiteturas de implementação de laços de controle, as quais se diferem basicamente pelo local na arquitetura do sistema de controle em rede em que o controlador será executado. Optou-se pela análise do comportamento do protocolo WirelessHART numa arquitetura que considera o módulo de controle localizado num dispositivo host, o qual se comunica via HART-UDP com o gateway da rede. Para a análise da proposta desta dissertação foram descritos os mecanismos necessários para a realização do laço de controle sobre uma rede WirelessHART real, em um ambiente que apresenta todas as características de uma instalação industrial. Os resultados obtidos mostram que, com a arquitetura proposta, o laço de controle apresenta latências não determinísticas. Para a realização deste trabalho, foram apresentados dois estudos de caso: (i) o controle de uma válvula comumente utilizada na indústria de petróleo; (ii) e um processo simulado, que considera um controlador baseado em eventos, onde o sinal de controle é calculado de acordo com os tempos de comunicação permitidos pela rede entre o controlador e o processo. Os resultados obtidos mostram que é possível efetuar controle apesar dos atrasos ocasionados pela rede, desde que sejam levados em conta estes atrasos no cálculo do sinal de controle, podendo assim mostrar há degradação no desempenho do sistema sob controle.pt_BR
dc.description.abstractThis work analyzes the use of WirelessHART protocol for the implementation of closed-loop control systems. It discusses possible architectures for implementing control loops, which differ by the location where the controller is executing. For the performance evaluation of the WirelessHART protocol behavior, an architecture that considers the control module located in a device, which communicates via Hart-UDP with the network gateway. The Experimental evaluations presented in this dissertation were performed in a setting that has all the characteristics of an industrial installation. The results showed that in the proposed architecture, the control loop has not deterministic latencies. Two case studies were carried on: (i) the control of a valve commonly used in oil and gas industrial applications; (ii) and a simulated process that considers an event-based controller where the control signal is calculated according to the communication time allowed by the network between the controller and the process. The results show that it is possible to perform control despite network delays, when taking into account the delays in the calculation of the control signal.en
dc.format.mimetypeapplication/pdf
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectElectrical engineeringen
dc.subjectRedes sem fiopt_BR
dc.subjectSistemas de controlept_BR
dc.subjectSignal processingen
dc.subjectControle automáticopt_BR
dc.subjectAutomation and controlen
dc.subjectAutomação industrialpt_BR
dc.subjectElectronic instrumentationen
dc.titleAnálise do impacto da comunicação em redes wirelesshart no desempenho de sistemas de controlept_BR
dc.typeDissertaçãopt_BR
dc.identifier.nrb001025066pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentEscola de Engenhariapt_BR
dc.degree.programPrograma de Pós-Graduação em Engenharia Elétricapt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2016pt_BR
dc.degree.levelmestradopt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples