dc.description.abstractA mensuração da pressão intraocular (PIO) é essencial para o exame oftálmico, pois permite o diagnóstico de doenças oftálmicas como uveíte e glaucoma, além de auxiliar no monitoramento das cirurgias intraoculares. Objetivou-se comparar a tonometria de rebote com a tonometria de aplanação em equinos. Além disso, determinar a reprodutibilidade dos valores obtidos em ambos os aparelhos. A PIO foi aferida em 30 equinos da raça Crioula, machos ou fêmeas, com idade entre um e 16 anos utilizando o tonômetro de rebote (TonoVet®) e o tonômetro de aplanação (Tonopen Avia®). Previamente a aferição da PIO, todos os animais foram submetidos ao exame oftálmico incluindo, avaliação dos reflexos pupilares, teste da lágrima de Schirmer, prova da fluoresceína e biomicroscopia com lâmpada de fenda portátil. Foram utilizados apenas bulbos oculares hígidos. A análise estatística foi feita com ANOVA e teste t de Student. A reprodutibilidade foi avaliada pelo cálculo do coeficiente de correlação intraclasse (ICC). A média da PIO foi de 26,16 ± 5,13 mmHg utilizando o tonômetro de rebote e de 22,55 ±7,32 mmHg com o tonômetro de aplanação. A média da PIO de acordo com o avaliador utilizando o tonômetro de rebote foi de 25,27 ± 4,9 mmHg para o examinador A, 25,80 ± 5,2 mmHg para o examinador B e de 27,40 ± 5,1 mmHg para o examinador C. Com o tonômetro de aplanação as médias obtidas foram de 20,03 ± 4,5 mmHg com o examinador A, 19,67 ± 6,0 mmHg com o examinador B e de 27,97 ± 10,3 mmHg com o examinador C (p<2,3). O ICC foi de 0,18 para o tonômetro de aplanação e de 0,41 para o tonômeto de rebote. Os valores da pressão intraocular média obtidos com o tonômetro de rebote são superestimados quando comparados aos valores obtidos com o tonômetro de Tonopen Avia® em equinos saudáveis. Comparativamente ao Tonopen Avia® os valores obtidos com o Tonovet® demonstraram maior reprodutibilidade.pt_BR
dc.description.abstractThe measurement of intraocular pressure (IOP) is essential for the ophthalmic examination, as it allows the diagnosis of eye diseases such as uveitis and glaucoma, as well as aid in the monitoring of intraocular surgery. This study aimed to compare the mean intraocular pressure (IOP) values in horses obtained by three different examiners using the rebound and applanation tonometer’s. Each examiner measured the IOP of 30 “Crioulo” horses, males or females, aged one to 16 years old, using rebound tonometer and applanation tonometer. Previous to the experiment an ophthalmic examination was performed in horses. Only animals without alterations were selected. Three veterinarians measured IOP with rebound (Tonovet®) and applanation tonometer’s (TonoPen Avia®). Comparisons were made using ANOVA and student t test. Intraclass correlation coefficient (ICC) was calculated for reproducibility. IOP measurements resulted in mean values of 26.16 ± 5.13 mmHg for rebound tonometer and 22.55 ±7.32 mmHg for applanation tonometer. These values were different on statistical analysis. Rebound tonometer mean values, according with the examiner, were: A 25.27 ± 4.9 mmHg, B 25.80 ± 5.2, C 27.40 ± 5.1 mmHg. For applanation tonometer the mean IOP for examiner A (20.03 ± 4.5 mmHg), B (19.67 ± 6.0 mmHg), C (27.97 ± 10.3 mmHg). With the Tonopen Avia® tonometer examiner C measured higher IOP’s than examiners A and B. Intraclass correlation coefficient was 0.41 for rebound tonometer was 0.18 for applanation tonometer. It was observed that the values obtained with the Tonovet® were overestimated compared to Tonopen Avia® in healthy horses. When compared with Tonopen Avia® values obtained with the Tonovet® showed a higher reproducibility.en
dc.format.mimetypeapplication/pdf
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectTonometryen
dc.subjectOftalmologia Veterináriapt_BR
dc.subjectTonometria ocularpt_BR
dc.subjectRebounden
dc.subjectApplanationen
dc.subjectPressão intraocularpt_BR
dc.subjectReproducibilityen
dc.subjectEquinospt_BR
dc.subjectOftalmologia Veterináriapt_BR
dc.titlePressão intraocular média obtida por três diferentes avaliadores utilizando os tonômetros de rebote e de aplanação em equinospt_BR
dc.typeDissertaçãopt_BR
dc.identifier.nrb000998275pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentFaculdade de Veterináriapt_BR
dc.degree.programPrograma de Pós-Graduação em Medicina Animal: Equinospt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2016pt_BR
dc.degree.levelmestradopt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples