Desempenho de reatores biológicos aeróbios de leito fluidizado inverso na remoçao de carga orgânica
dc.contributor.advisor | Monteggia, Luiz Olinto | pt_BR |
dc.contributor.author | Zim, Graziela | pt_BR |
dc.date.accessioned | 2008-05-01T04:12:27Z | pt_BR |
dc.date.issued | 2006 | pt_BR |
dc.identifier.uri | http://hdl.handle.net/10183/12687 | pt_BR |
dc.description.abstract | Este estudo avaliou a eficiência de reatores biológicos aeróbios de leito fluidizado inverso na remoção de matéria orgânica quando submetidos a diferentes condições operacionais (vazão de recirculação e carga orgânica aplicada). O experimento, em escala de laboratório, foi realizado em três reatores cilíndricos (R1, R2 e R3) com altura total de 2,00 m, diâmetro interno de 0,10 m e volume útil de 15,70 L. Como meio suporte para o desenvolvimento do biofilme foram utilizadas partículas de polipropileno (PP) em volume equivalente a 40% do volume útil do reator. O afluente entrava nos reatores pelo topo e saía pelo fundo e o oxigênio era fornecido através de um aerador poroso. Os reatores R1, R2 e R3 foram operados com vazão de recirculação de 2,50 L/min, 4,00 L/min e 5,50 L/min, respectivamente, durante todo período experimental. Os reatores foram alimentados com esgoto sintético caracteristicamente doméstico e o experimento consistiu de três etapas, conforme a carga orgânica aplicada: Etapa de Menor Carga – 0,70 Kg DQO/m3.dia; Etapa de Carga Intermediária – 1,70 Kg DQO/m3.dia e Etapa de Maior Carga – 3,90 Kg DQO/m3.dia. A vazão de alimentação foi mantida constante durante todo período experimental correspondendo ao TDH de 12 horas.O acompanhamento dos reatores foi realizado com medidas de DQO, sólidos livres (suspensão) e aderidos (biofilme). Foi determinada também a velocidade ascensional das biopartículas no meio líquido, tendo como motivo a identificação das possíveis causas da expansão excessiva ocorrida durante a realização do experimento. Os resultados obtidos demonstraram elevada eficiência de remoção carbonácea em termos de DQO, com médias superior a 93% na etapa de Carga Intermediária e em torno de 90% para a etapa de Maior Carga. Conforme avaliação estatística, não houve evidências de que a vazão de recirculação tenha efeito sobre a eficiência de remoção carbonácea. O aumento da carga orgânica afluente reduziu de forma significativa a eficiência de remoção carbonácea apenas no reator de menor vazão de recirculação. Em relação à quantidade de sólidos voláteis, o aumento da vazão de recirculação resultou em aumento dos sólidos voláteis aderidos, porém não foi identificado efeito sobre a quantidade de sólidos voláteis livres.O aumento de carga aplicada resultou em aumento significativo na quantidade média de sólidos voláteis livres nos reatores. Quanto aos sólidos voláteis aderidos, o acréscimo de carga afluente repercutiu de forma diferente nos três reatores: para a menor vazão de recirculação houve redução na massa de sólidos voláteis aderidos, para a vazão de recirculação intermediária ocorreu aumento da massa de sólidos voláteis aderidos e para a maior vazão de recirculação o aumento da carga aplicada não influenciou a quantidade de sólidos aderidos voláteis presentes no reator. A velocidade ascensional média das biopartículas diminuiu com o aumento da vazão de recirculação, significando que quanto maior a vazão de recirculação maior a densidade das biopartículas. | pt_BR |
dc.description.abstract | This study evaluated the efficiency of down flow aerobic fluidized bed reactors for the removal of organic mater submitted to different operational conditions (recirculation flow and applied organic load). The experiment was run on 3 cylindrical lab scale reactors (R1, R2 and R3) with 2 m total height, 0.10 m internal diameter and working volume of 15.70 L. Polypropylene particles were used as the support material for the development of the biofilm occupying 40% of the working volume of the reactors. The influent were applied at the top of the columns and withdraw from the bottom and the oxygen was supplied throughout a porous stone. The reactors R1, R2 and R3 were operated with recirculation flow of 2,50, 4.00 and 5.50 L. min-1, respectively, throughout the experimental work.The reactors were fed with synthetic wastewater similar to sanitary wastewater and the experiment was performed in 3 steps, according to the applied organic loading rate, namely: Lower Load - 0,70 Kg COD/m3.dia; Intermediate Load - 1,70 Kg COD/m3.dia; Higher Load - 3,90 Kg COD/m3.dia. The feeding flow was maintained constant throughout the experiment to obtain HDT equal to 12 hours. The reactors were monitored with conventional parameters such as COD, free suspended solids and attached suspended solids (biofilm). The upflow velocity of the bioparticles in the liquid phase was also determined with the purpose to identify the potential causes of the excessive expansion of the bed observed during the experimental work. The experimental results demonstrated high efficiency of carbonaceous COD removal, with average values above 93 % during the Intermediate Load step and around 90 % for the Higher Load. According to statistical evaluation, the recirculation flow did not provided significant effect upon the carbonaceous organic matter removal. The increase in applied organic load caused a significant decrease only to the reactor operated with the lower recirculation flow. Regarding the amount of volatile solids, the increase of the recirculation flow resulted in the increase of the attached volatile solids, however it was not identified any effect upon the amount of free volatile solids. The increase of applied organic load resulted in significant increase of the amount of the free volatile solids in the reactors. Regarding the attached volatile solids, the increase of applied organic load resulted in misleading behavior of the reactors, as follows: the lower recirculation flow resulted in a reduction of the amount of attached volatile solids; the intermediate recirculation flow resulted in an increase of the attached volatile solids, while it was not observed any significant variation in the amount of attached volatile solids inside the reactor operated with the higher recirculation flow. The average accession velocity of the bioparticles decreased with the increase of the recirculation flow, implying that the recirculation flow resulted in higher values of the bioparticles density. | en |
dc.format.mimetype | application/pdf | |
dc.language.iso | por | pt_BR |
dc.rights | Open Access | en |
dc.subject | Tratamento de efluentes | pt_BR |
dc.subject | Leitos fluidizados | pt_BR |
dc.subject | Reatores biologicos | pt_BR |
dc.subject | Biofilmes | pt_BR |
dc.subject | Desinfecção | pt_BR |
dc.subject | Vazão | pt_BR |
dc.title | Desempenho de reatores biológicos aeróbios de leito fluidizado inverso na remoçao de carga orgânica | pt_BR |
dc.type | Dissertação | pt_BR |
dc.identifier.nrb | 000605877 | pt_BR |
dc.degree.grantor | Universidade Federal do Rio Grande do Sul | pt_BR |
dc.degree.department | Instituto de Pesquisas Hidráulicas | pt_BR |
dc.degree.program | Programa de Pós-Graduação em Recursos Hídricos e Saneamento Ambiental | pt_BR |
dc.degree.local | Porto Alegre, BR-RS | pt_BR |
dc.degree.date | 2006 | pt_BR |
dc.degree.level | mestrado | pt_BR |
Files in this item
This item is licensed under a Creative Commons License
-
Engineering (7412)